29
IRUS Total
Downloads
  Altmetric

Characteristics of fine and ultrafine aerosols in the London underground.

File Description SizeFormat 
1-s2.0-S0048969722064142-main.pdfPublished version6.53 MBAdobe PDFView/Open
Title: Characteristics of fine and ultrafine aerosols in the London underground.
Authors: Kumar, P
Zavala-Reyes, JC
Kalaiarasan, G
Abubakar-Waziri, H
Young, G
Mudway, I
Dilliway, C
Lakhdar, R
Mumby, S
Kłosowski, MM
Pain, CC
Adcock, IM
Watson, JS
Sephton, MA
Chung, KF
Porter, AE
Item Type: Journal Article
Abstract: Underground railway systems are recognised spaces of increased personal pollution exposure. We studied the number-size distribution and physico-chemical characteristics of ultrafine (PM0.1), fine (PM0.1-2.5) and coarse (PM2.5-10) particles collected on a London underground platform. Particle number concentrations gradually increased throughout the day, with a maximum concentration between 18:00 h and 21:00 h (local time). There was a maximum decrease in mass for the PM2.5, PM2.5-10 and black carbon of 3.9, 4.5 and ~ 21-times, respectively, between operable (OpHrs) and non-operable (N-OpHrs) hours. Average PM10 (52 μg m-3) and PM2.5 (34 μg m-3) concentrations over the full data showed levels above the World Health Organization Air Quality Guidelines. Respiratory deposition doses of particle number and mass concentrations were calculated and found to be two- and four-times higher during OpHrs compared with N-OpHrs, reflecting events such as train arrival/departure during OpHrs. Organic compounds were composed of aromatic hydrocarbons and polycyclic aromatic hydrocarbons (PAHs) which are known to be harmful to health. Specific ratios of PAHs were identified for underground transport that may reflect an interaction between PAHs and fine particles. Scanning transmission electron microscopy (STEM) chemical maps of fine and ultrafine fractions show they are composed of Fe and O in the form of magnetite and nanosized mixtures of metals including Cr, Al, Ni and Mn. These findings, and the low air change rate (0.17 to 0.46 h-1), highlight the need to improve the ventilation conditions.
Issue Date: 1-Feb-2023
Date of Acceptance: 5-Oct-2022
URI: http://hdl.handle.net/10044/1/100405
DOI: 10.1016/j.scitotenv.2022.159315
ISSN: 0048-9697
Publisher: Elsevier
Journal / Book Title: Science of the Total Environment
Volume: 858
Issue: Pt 1
Copyright Statement: © 2022 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
Sponsor/Funder: Engineering & Physical Science Research Council (EPSRC)
Engineering and Physical Sciences Research Council
Funder's Grant Number: EP/T003189/1
EP/T003189/1
Keywords: Exposure assessment
Metal content
Particle characterisation
Subway station
Underground pollution
Exposure assessment
Metal content
Particle characterisation
Subway station
Underground pollution
Environmental Sciences
Publication Status: Published
Conference Place: Netherlands
Article Number: ARTN 159315
Online Publication Date: 2022-10-22
Appears in Collections:Materials
Earth Science and Engineering
National Heart and Lung Institute
Faculty of Medicine
Faculty of Natural Sciences



This item is licensed under a Creative Commons License Creative Commons