Altmetric

Changing carbon dioxide and water budgets from deforestation and habitat modification

Title: Changing carbon dioxide and water budgets from deforestation and habitat modification
Authors: Riutta, T
Ewers, RM
Malhi, Y
Majalap, N
Item Type: Dataset
Abstract: SAFE Intensive Carbon Plots, part of the Global Ecosystem Monitoring (GEM) network, see http://gem.tropicalforests.ox.ac.uk/ Total soil respiration is measured at 25 points per plot, in the middle of each subplot (16 points per plot in OP, in subplot corners), using 12 cm diameter PVC collars inserted into approximately 5 cm depth Partitioned respiration is measured at four points per plot, a using a cluster of six collars (see below) Disturbance experiment in the plot centre All the methods and installation is described in detail in the GEM Intensive Carbon Plots manual, available at http://gem.tropicalforests.ox.ac.uk/files/rainfor-gemmanual.v3.0.pdf The aim is to measure monthly, but in practice the measurement interval is almost always longer (problems with access, staffing and instruments) EGM-4 infrared CO2 analyser and SRC-1 respiration chamber (PP Systems) Chamber closure time is 124 seconds, CO2 concentration inside the chamber is recorded every 5 s. Flux is calculated from the linear change in concentration in the chamber headspace
SAFE Intensive Carbon Plots, part of the Global Ecosystem Monitoring (GEM) network, see http://gem.tropicalforests.ox.ac.uk/ Total soil respiration is measured at 25 points per plot, in the middle of each subplot (16 points per plot in OP, in subplot corners), using 12 cm diameter PVC collars inserted into approximately 5 cm depth Partitioned respiration is measured at four points per plot, a using a cluster of six collars (see below) Disturbance experiment in the plot centre All the methods and installation is described in detail in the GEM Intensive Carbon Plots manual, available at http://gem.tropicalforests.ox.ac.uk/files/rainfor-gemmanual.v3.0.pdf The aim is to measure monthly, but in practice the measurement interval is almost always longer (problems with access, staffing and instruments) EGM-4 infrared CO2 analyser and SRC-1 respiration chamber (PP Systems) Chamber closure time is 124 seconds, CO2 concentration inside the chamber is recorded every 5 s. Flux is calculated from the linear change in concentration in the chamber headspace
Content Version: 1
Issue Date: 3-Jul-2019
URI: http://hdl.handle.net/10044/1/75714
DOI: 10.5281/zenodo.3266771
Keywords: Soil respiration
Carbon dioxide
CO2
SAFE core data
SAFE project
Carbon plot
Soil moisture
Soil temperature
Notes: These data were collected as part of research funded by: Sime Darby Foundation (Grant, SAFE Core data) European Research Council Advanced Investigator Grant, GEM-TRAIT (Grant, Grant number 321131) NERC Human-Modified Tropical Forests Programme: Biodiversity And Land-use Impacts on tropical ecosystem function (BALI) Project (Grant, NE/K016369/1) NERC standard grant: The multi-year impacts of the 2015/2016 El NiƱo on the carbon cycle of tropical forests worldwide (Grant, NE/P001092/1) HSBC Malaysia (Grant) The University of Zurich (Grant)
Access Data Notes: Closed access
Appears in Collections:Faculty of Natural Sciences - Research Data



Unless otherwise indicated, items in Spiral are protected by copyright and are licensed under a Creative Commons Attribution NonCommercial NoDerivatives License.

Creative Commons