85
IRUS Total
Downloads
  Altmetric

A real-time method for decoding the neural drive to muscles using single-channel intra-muscular EMG recordings

File Description SizeFormat 
s0129065717500253.pdfPublished version794.67 kBAdobe PDFView/Open
Title: A real-time method for decoding the neural drive to muscles using single-channel intra-muscular EMG recordings
Authors: Karimimehr, S
Marateb, H
Muceli, S
Mansourian, M
Mannas, M
Farina, D
Item Type: Journal Article
Abstract: The neural command from motor neurons to muscles — sometimes referred to as the neural drive to muscle — can be identified by decomposition of electromyographic (EMG) signals. This approach can be used for inferring the voluntary commands in neural interfaces in patients with limb amputations. This paper proposes for the first time an innovative method for fully automatic and real-time intramuscular EMG (iEMG) decomposition. The method is based on online single-pass density-based clustering and adaptive classification of bivariate features, using the concept of potential measure. No attempt was made to resolve superimposed motor unit action potentials. The proposed algorithm was validated on sets of simulated and experimental iEMG signals. Signals were recorded from the biceps femoris long-head, vastus medialis and lateralis and tibialis anterior muscles during low-to-moderate isometric constant-force and linearly-varying force contractions. The average number of missed, duplicated and erroneous clusters for the examined signals was 0.5±0.8, 1.2±1.0, and 1.0±0.8, respectively. The average decomposition accuracy (defined similar to signal detection theory but without using True Negatives in the denominator) and coefficient of determination (variance accounted for) for the cumulative discharge rate estimation were 70±9%, and 94±5%, respectively. The time cost for processing each 200 ms iEMG interval was 43 ± 16 (21–97) ms. However, computational time generally increases over time as a function of frames/signal epochs. Meanwhile, the incremental accuracy defined as the accuracy of real-time analysis of each signal epoch, was 74 ± 18% for epochs recorded after initial one second. The proposed algorithm is thus a promising new tool for neural decoding in the next-generation of prosthetic control.
Issue Date: 21-Apr-2017
Date of Acceptance: 11-Mar-2017
URI: http://hdl.handle.net/10044/1/45587
DOI: https://dx.doi.org/10.1142/S0129065717500253
ISSN: 1793-6462
Publisher: World Scientific Publishing
Journal / Book Title: International Journal of Neural Systems
Volume: 27
Issue: 6
Copyright Statement: © The Author(s). This is an Open Access article published by World Scientific Publishing Company. It is distributed under the terms of the Creative Commons Attribution 4.0 (CC-BY) License. Further distribution of this work is permitted, provided the original work is properly cited.
Keywords: Artificial Intelligence & Image Processing
0801 Artificial Intelligence And Image Processing
1702 Cognitive Science
Publication Status: Published
Article Number: 1750025
Appears in Collections:Bioengineering
Faculty of Engineering