Ionic hydrogel sensors for low-latency high-accuracy
3D reconstruction of soft robotic endoscope
3D reconstruction of soft robotic endoscope
File(s) CR_PHYS_SCI_D_26_00635R1_Main_Latex 1.pdf (324.95 KB) CR_PHYS_SCI_D_26_00635R1-SI.pdf (24.58 MB)
Accepted version
Supporting information
Author(s)
Type
Journal Article
Abstract
Continuous shape sensing remains a major barrier to deploying soft robotic endoscopes, because existing solutions often compromise structural compliance, require expensive instrumentation, or provide only limited embedded feedback. Here, we report an integrated soft sensing system based on an array
of ionic hydrogel strain sensors, enabling low-latency, high-accuracy three-dimensional shape reconstruction of a soft endoscope tip. Optimization across NaCl concentration, applied voltage, and strain rate identifies ideal composition and operating conditions jointly balancing gauge factor, strain-rate independence, and mechanical robustness. Three optimized sensors are then integrated around the circumference of a soft pneumatic actuator, addressing adhesion, dehydration, and signal stability under actuation. Continuous three-dimensional shape reconstruction is achieved using a Frenet–Serret-based model, and a simple delay-compensation strategy reduces the relative tip-position error from 10.08% to 5.92% of the actuator arc length. This offers a low-cost, compliant, disposable-compatible route to proprioceptive sensing for minimally invasive intervention.
of ionic hydrogel strain sensors, enabling low-latency, high-accuracy three-dimensional shape reconstruction of a soft endoscope tip. Optimization across NaCl concentration, applied voltage, and strain rate identifies ideal composition and operating conditions jointly balancing gauge factor, strain-rate independence, and mechanical robustness. Three optimized sensors are then integrated around the circumference of a soft pneumatic actuator, addressing adhesion, dehydration, and signal stability under actuation. Continuous three-dimensional shape reconstruction is achieved using a Frenet–Serret-based model, and a simple delay-compensation strategy reduces the relative tip-position error from 10.08% to 5.92% of the actuator arc length. This offers a low-cost, compliant, disposable-compatible route to proprioceptive sensing for minimally invasive intervention.
Date Acceptance
2026-10-09
Citation
Cell Reports Physical Science
ISSN
2666-3864
Publisher
Elsevier
Journal / Book Title
Cell Reports Physical Science
Copyright Statement
Copyright This paper is embargoed until publication. Once published the Version of Record (VoR) will be available on immediate open access.
Publication Status
Accepted