Title: Development of a tool to detect small airways dysfunction in asthma clinical practice
Authors: Kocks, J
Van der Molen, T
Voorham, J
Baldi, S
Van den Berge, M
Brightling, C
Fabbri, LM
Kraft, M
Nicolini, G
Papi, A
Rabe, KF
Siddiqui, S
Singh, D
Vonk, J
Leving, M
Flokstra-de Blok, B
Item Type: Journal Article
Abstract: BACKGROUND: Small airways dysfunction (SAD) in asthma is difficult to measure and a gold standard is lacking. The aim of this study was to develop a simple tool including items of the Small Airways Dysfunction Tool (SADT) questionnaire, basic patient characteristics and respiratory tests available depending on the clinical setting to predict SAD in asthma. METHODS: This study was based on the data of the multinational ATLANTIS (Assessment of Small Airways Involvement in Asthma) study including the earlier developed SADT questionnaire. Key SADT items together with clinical information were now used to build logistic regression models to predict SAD group (less likely or more likely to have SAD). Diagnostic ability of the models was expressed as area under the receiver operating characteristic curve (AUC) and positive likelihood ratio (LR+). RESULTS: SADT item 8, "I sometimes wheeze when I am sitting or lying quietly", and the patient characteristics age, age at asthma diagnosis and body mass index could reasonably well detect SAD (AUC 0.74, LR+ 2.3). The diagnostic ability increased by adding spirometry (percentage predicted forced expiratory volume in 1 s: AUC 0.87, LR+ 5.0) and oscillometry (resistance difference between 5 and 20 Hz and reactance area: AUC 0.96, LR+ 12.8). CONCLUSIONS: If access to respiratory tests is limited (e.g. primary care in many countries), patients with SAD could reasonably well be identified by asking about wheezing at rest and a few patient characteristics. In (advanced) hospital settings patients with SAD could be identified with considerably higher accuracy using spirometry and oscillometry.
Issue Date: 1-Mar-2023
Date of Acceptance: 31-Oct-2022
URI: http://hdl.handle.net/10044/1/105269
DOI: 10.1183/13993003.00558-2022
ISSN: 0903-1936
Publisher: European Respiratory Society
Journal / Book Title: European Respiratory Journal
Volume: 61
Issue: 3
Copyright Statement: ©The authors 2023. This version is distributed under the terms of the Creative Commons Attribution Non- Commercial Licence 4.0. For commercial reproduction rights and permissions contact permissions@ersnet.org
Publication Status: Published
Conference Place: England
Article Number: ARTN 2200558
Online Publication Date: 2023-03-30
Appears in Collections:National Heart and Lung Institute



This item is licensed under a Creative Commons License Creative Commons