2
IRUS Total
Downloads
  Altmetric

A computational study of the effects of size, location, and number of tears on haemodynamics in surgically repaired type A aortic dissection

File Description SizeFormat 
fcvm-10-1215720.pdfPublished version14 MBAdobe PDFView/Open
Title: A computational study of the effects of size, location, and number of tears on haemodynamics in surgically repaired type A aortic dissection
Authors: Motoki, K
Zhu, Y
Mirsadraee, S
Rosendahl, U
Pepper, J
Xu, X
Item Type: Journal Article
Abstract: Objective: This study aimed to comprehensively examine the roles of size, location, and number of tears in the progression of surgically repaired type A aortic dissection (TAAD) by assessing haemodynamic changes through patient-specific computational fluid dynamic (CFD) simulations. Methods: Two patient-specific TAAD geometries with replaced ascending aorta were reconstructed based upon computed 15 tomography (CT) scans, after which 10 hypothetical models (5 per patient) with different tear configurations were artificially created. CFD simulations were performed on all the models under physiologically realistic boundary conditions. Results: Our simulation results showed that increasing either the size or number of the re-entry tears reduced the luminal pressure difference (LPD) and maximum time-averaged wall shear stress (TAWSS), as well as areas exposed to abnormally high or low TAWSS values. Models with a large re-entry tear outperformed the others by reducing the maximum LPD by 1.88 mmHg and 7.39 mmHg, for patients 1 and 2, respectively. Moreover, proximally located re-entry tears in the descending aorta were more effective at reducing LPD than distal re-entry tears. Discussion: These computational results indicate that the presence of a relatively large re-entry tear in the proximal descending aorta might help stabilize post-surgery aortic growth. This finding has important implications for the management and risk stratification of surgically repaired TAAD patients. Nevertheless, further validation in a large patient cohort is needed.
Issue Date: 14-Jun-2023
Date of Acceptance: 5-Jun-2023
URI: http://hdl.handle.net/10044/1/104749
DOI: 10.3389/fcvm.2023.1215720
ISSN: 2297-055X
Publisher: Frontiers Media S.A.
Start Page: 1
End Page: 14
Journal / Book Title: Frontiers in Cardiovascular Medicine
Volume: 10
Copyright Statement: © 2023 Motoki, Zhu, Mirsadraee, Rosendahl, Pepper and Xu. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
Publication Status: Published
Article Number: 1215720
Online Publication Date: 2023-06-14
Appears in Collections:Chemical Engineering
Faculty of Engineering



This item is licensed under a Creative Commons License Creative Commons