The acute effect of continuous positive airway pressure titration on blood pressure in awake overweight/obese patients with obstructive sleep apnoea
File(s) Figure 2.png (63.84 KB) BP_Table 1.docx (36.66 KB)
Supporting information
Supporting information
Author(s)
Type
Journal Article
Abstract
Objectives: Continuous positive airway pressure (CPAP) improves upper airway obstruction in patients with obstructive sleep apnoea (OSA), who often are overweight-obese. Although it is thought that CPAP improves long-term blood pressure control (BP), the impact of acute and short-term CPAP use on the cardiovascular system in obese patients has not been described in detail.
Methods: Obese patients (body mass index, BMI > 25 kg/m2) with OSA were studied awake, supine during incremental CPAP titration (4–20 cmH2O, +2 cmH2O/3 mins). BP was measured continuously with a beat-to-beat BP monitor (Ohmeda 2300, Finapres Medical Systems, Amsterdam/NL), BP variability (BPV) was calculated as the standard deviation of BP at each CPAP level, the 95% confidence interval (95%CI) was calculated and changes in BP and BPV were reported.
Results: 15 patients (12 male, 48 ± 10) years, BMI 38.9 ± 5.8 kg/m2) were studied; the baseline BP was 131.0 ± 10.2/85.1 ± 9.1 mmHg. BP and BPV increased linearly with CPAP titration (systolic BP r = 0.960, p < .001; diastolic BP r = 0.961, p < .001; systolic BPV r = 0.662, p = .026; diastolic BPV r = 0.886, p < .001). The systolic BP increased by +17% (+23.15 (7.9, 38.4) mmHg; p = .011) and the diastolic BP by +23% (+18.27 (2.33, 34.21) mmHg; p = .009), when titrating CPAP to 20 cmH2O. Systolic BPV increased by +96% (+5.10 (0.67, 9.53) mmHg; p < .001) and was maximal at 14 cmH2O, and diastolic BPV by +97% (+3.02 (0.26, 5.78) mmHg; p < .001) at 16 cmH2O.
Conclusion: Short-term incremental CPAP leads to significant increases in BP and BPV in obese patients with OSA while awake. Careful titration of pressures is required to minimise the risk of nocturnal awakenings while improving BP control.
Methods: Obese patients (body mass index, BMI > 25 kg/m2) with OSA were studied awake, supine during incremental CPAP titration (4–20 cmH2O, +2 cmH2O/3 mins). BP was measured continuously with a beat-to-beat BP monitor (Ohmeda 2300, Finapres Medical Systems, Amsterdam/NL), BP variability (BPV) was calculated as the standard deviation of BP at each CPAP level, the 95% confidence interval (95%CI) was calculated and changes in BP and BPV were reported.
Results: 15 patients (12 male, 48 ± 10) years, BMI 38.9 ± 5.8 kg/m2) were studied; the baseline BP was 131.0 ± 10.2/85.1 ± 9.1 mmHg. BP and BPV increased linearly with CPAP titration (systolic BP r = 0.960, p < .001; diastolic BP r = 0.961, p < .001; systolic BPV r = 0.662, p = .026; diastolic BPV r = 0.886, p < .001). The systolic BP increased by +17% (+23.15 (7.9, 38.4) mmHg; p = .011) and the diastolic BP by +23% (+18.27 (2.33, 34.21) mmHg; p = .009), when titrating CPAP to 20 cmH2O. Systolic BPV increased by +96% (+5.10 (0.67, 9.53) mmHg; p < .001) and was maximal at 14 cmH2O, and diastolic BPV by +97% (+3.02 (0.26, 5.78) mmHg; p < .001) at 16 cmH2O.
Conclusion: Short-term incremental CPAP leads to significant increases in BP and BPV in obese patients with OSA while awake. Careful titration of pressures is required to minimise the risk of nocturnal awakenings while improving BP control.
Date Issued
2018-08-01
Date Acceptance
2018-02-18
Citation
Blood Pressure, 2018, 27 (4), pp.206-214
ISSN
0803-7051
Publisher
Taylor & Francis
Start Page
206
End Page
214
Journal / Book Title
Blood Pressure
Volume
27
Issue
4
Copyright Statement
© 2018 Informa UK Ltd, trading as Taylor & Francis Group. This is an Accepted Manuscript of an article published by Taylor & Francis in Blood Press on 23 Feb 2018, available online: https://www.tandfonline.com/doi/full/10.1080/08037051.2018.1443391
Subjects
Hypertension
cardiovascular
obesity
sympathetic
variability
1103 Clinical Sciences
Cardiovascular System & Hematology
Publication Status
Published
Date Publish Online
2018-02-23