Development of novel magnetic resonance methods for advanced parametric mapping of the right ventricle

File Description SizeFormat 
Roehl-M-2022-PhD-Thesis.pdfThesis31.64 MBAdobe PDFView/Open
Title: Development of novel magnetic resonance methods for advanced parametric mapping of the right ventricle
Authors: Roehl, Malte
Item Type: Thesis or dissertation
Abstract: The detection of diffuse fibrosis is of particular interest in congenital heart disease patients, including repaired Tetralogy of Fallot (rTOF), as clinical outcome is linked to the accurate identification of diffuse fibrosis. In the Left Ventricular (LV) myocardium native T1 mapping and Diffusion Tensor Cardiac Magnetic Resonance (DT-CMR) are promising approaches for detection of diffuse fibrosis. In the Right Ventricle (RV) current techniques are limited due to the thinner, mobile and complex shaped compact myocardium. This thesis describes technical development of RV tissue characterisation methods. An interleaved variable density spiral DT-CMR method was implemented on a clinical 3T scanner allowing both ex and in vivo imaging. A range of artefact corrections were implemented and tested (gradient timing delays, off-resonance and T2* corrections). The off- resonance and T2* corrections were evaluated using computational simulation demonstrating that for in vivo acquisitions, off-resonance correction is essential. For the first-time high-resolution Stimulated Echo Acquisition Mode (STEAM) DT-CMR data was acquired in both healthy and rTOF ex-vivo hearts using an interleaved spiral trajectory and was shown to outperform single-shot EPI methods. In vivo the first DT-CMR data was shown from the RV using both an EPI and an interleaved spiral sequence. Both sequences provided were reproducible in healthy volunteers. Results suggest that the RV conformation of cardiomyocytes differs from the known structure in the LV. A novel STEAM-SAturation-recovery Single-sHot Acquisition (SASHA) sequence allowed the acquisition of native T1 data in the RV. The excellent blood and fat suppression provided by STEAM is leveraged to eliminate partial fat and blood signal more effectively than Modified Look-Locker Imaging (MOLLI) sequences. STEAM-SASHA T1 was validated in a phantom showing more accurate results in the native myocardial T1 range than MOLLI. STEAM-SASHA demonstrated good reproducibility in healthy volunteers and initial promising results in a single rTOF patient.
Content Version: Open Access
Issue Date: Nov-2021
Date Awarded: May-2022
URI: http://hdl.handle.net/10044/1/97440
DOI: https://doi.org/10.25560/97440
Copyright Statement: Creative Commons Attribution NonCommercial Licence
Supervisor: Scott, Andrew
Gatehouse, Peter
Babu-Narayan, Sonya
Firmin, David
Sponsor/Funder: British Heart Foundation
Imperial College London
Funder's Grant Number: P62117
Department: National Heart & Lung Institute
Publisher: Imperial College London
Qualification Level: Doctoral
Qualification Name: Doctor of Philosophy (PhD)
Appears in Collections:National Heart and Lung Institute PhD theses



This item is licensed under a Creative Commons License Creative Commons