30
IRUS Total
Downloads
  Altmetric

Effect of high temperature service on the complex through-wall microstructure of centrifugally cast HP40 reformer tube

File Description SizeFormat 
2008.07429v2.pdfWorking paper8.83 MBAdobe PDFView/Open
Title: Effect of high temperature service on the complex through-wall microstructure of centrifugally cast HP40 reformer tube
Authors: Dessolier, T
McAuliffe, T
Hamer, WJ
Hermse, CGM
Britton, TB
Item Type: Working Paper
Abstract: Centrifugally cast reformer tubes are used in petrochemical plants for hydrogen production. Due to the conditions of hydrogen production, reformer tubes are exposed to high temperature which causes creep damage inside the microstructure. In this study, two different ex-service HP40 alloy reformer tubes which come from the same steam reformer unit have been compared by microstructural characterisation performed at a range of length scales from mm to um. Analyses performed by EBSD (Electron Backscatter Diffraction), EDS (Energy Dispersive X-ray Spectroscopy) and PCA (Principal Component Analysis) show that both tubes have similar microstructural constituents, with the presence of an austenitic matrix and M23C6, G phase and M6C carbides at the grain boundaries. Even if both tubes have a similar microstructure, one tube due to it localisation inside the steam reformer unit presents a region with more micro cracks which may indicate that this tube have accumulated more creep damage than the other one.
Issue Date: 26-Aug-2020
URI: http://hdl.handle.net/10044/1/87987
Publisher: arXiv
Copyright Statement: © 2020 The Author(s)
Sponsor/Funder: Shell Global Solutions International BV
Funder's Grant Number: PO 4550133349
Keywords: physics.app-ph
physics.app-ph
cond-mat.mtrl-sci
physics.app-ph
physics.app-ph
cond-mat.mtrl-sci
Notes: 21 pages, 9 figures and 5 tables
Publication Status: Published
Appears in Collections:Materials