322
IRUS Total
Downloads
  Altmetric

A pilot study in humans of microneedle sensor arrays for continuous glucose monitoring

File Description SizeFormat 
AcceptedVersion.pdfAccepted version1.02 MBAdobe PDFView/Open
Title: A pilot study in humans of microneedle sensor arrays for continuous glucose monitoring
Authors: Sharma, S
El-Laboudi, A
Reddy, M
Jugnee, N
Sivasubramaniyam, S
El Sharkawy, M
Georgiou, P
Johnston, D
Oliver, N
Cass, AEG
Item Type: Journal Article
Abstract: Although subcutaneously implanted continuous glucose monitoring (CGM) devices have been shown to support diabetes self-management, their uptake remains low due to a combination of high manufacturing cost and limited accuracy and precision arising from their invasiveness. To address these points, minimally invasive, a solid microneedle array-based sensor for continuous glucose monitoring is reported here. These intradermal solid microneedle CGM sensors are designed for low cost manufacturing. The tolerability and performance of these devices is demonstrated through clinical studies, both in healthy volunteers and participants with type 1 diabetes (T1D). The geometry of these solid microneedles allows them to penetrate dermal tissue without the need for an applicator. The outer surface of these solid microneedles are modified as glucose biosensors. The microneedles sit in the interstitial fluid of the skin compartment and monitor real-time changes in glucose concentration. Optical coherence tomography measurements revealed no major axial movement of the microneedles in the tissue. No significant adverse events were observed and low pain scores were reported when compared to catheter insertion, deeming it safe for clinical studies in T1D. These amperometric sensors also yielded currents that tracked venous blood glucose concentrations, showing a clinically acceptable correlation. Studies in people with T1D gave a mean absolute relative difference (MARD) of 9% (with respect to venous blood glucose) with over 94% of the data points in the A and B zones of the Clarke error grid. These findings provide baseline data for further device development and a larger clinical efficacy and acceptability study of this microneedle intradermal glucose sensor in T1D.
Issue Date: 14-May-2018
Date of Acceptance: 20-Mar-2018
URI: http://hdl.handle.net/10044/1/60223
DOI: https://dx.doi.org/10.1039/c8ay00264a
ISSN: 1759-9660
Start Page: 2088
End Page: 2095
Journal / Book Title: Analytical Methods
Volume: 10
Issue: 18
Copyright Statement: © The Royal Society of Chemistry 2018
Sponsor/Funder: National Institute for Health Research
Funder's Grant Number: II-LA-0313-20004
Keywords: Science & Technology
Physical Sciences
Life Sciences & Biomedicine
Technology
Chemistry, Analytical
Food Science & Technology
Spectroscopy
Chemistry
EVALUATING CLINICAL ACCURACY
VACCINE DELIVERY
BLOOD-GLUCOSE
DRUG
MICRODIALYSIS
SYSTEMS
PERFORMANCE
TISSUE
LINE
0301 Analytical Chemistry
0399 Other Chemical Sciences
Publication Status: Published
Online Publication Date: 2018-03-21
Appears in Collections:Chemistry
Biological and Biophysical Chemistry
Electrical and Electronic Engineering
Department of Medicine (up to 2019)
Department of Medicine (up to 2019)
Faculty of Natural Sciences
Faculty of Engineering