61
IRUS Total
Downloads
  Altmetric

A flexible wearable sensor for knee flexion assessment during gait

File Description SizeFormat 
1-s2.0-S0966636218303746-main.pdfPublished version535.61 kBAdobe PDFView/Open
Title: A flexible wearable sensor for knee flexion assessment during gait
Authors: Papi, E
Bo, YN
McGregor, A
Item Type: Journal Article
Abstract: Background: Gait analysis plays an important role in the diagnosis and management of patients with movement disorders but it is usually performed within a laboratory. Recently interest has shifted towards the possibility of conducting gait assessments in everyday environments thus facilitating long-term monitoring. This is possible by using wearable technologies rather than laboratory based equipment. Research question This study aims to validate a novel wearable sensor system’s ability to measure peak knee sagittal angles during gait. Methods: The proposed system comprises a flexible conductive polymer unit interfaced with a wireless acquisition node attached over the knee on a pair of leggings. Sixteen healthy volunteers participated to two gait assessments on separate occasions. Data was simultaneously collected from the novel sensor and a gold standard 10 camera motion capture system. The relationship between sensor signal and reference knee flexion angles was defined for each subject to allow the transformation of sensor voltage outputs to angular measures (degrees). The knee peak flexion angle from the sensor and reference system were compared by means of root mean square error (RMSE), absolute error, Bland-Altman plots and intra-class correlation coefficients (ICCs) to assess test-retest reliability. Results: Comparisons of knee peak flexion angles calculated from the sensor and gold standard yielded an absolute error of 0.35(±2.9°) and RMSE of 1.2(±0.4)°. Good agreement was found between the two systems with the majority of data lying within the limits of agreement. The sensor demonstrated high test-retest reliability (ICCs>0.8). Significance: These results show the ability of the sensor to monitor knee peak sagittal angles with small margins of error and in agreement with the gold standard system. The sensor has potential to be used in clinical settings as a discreet, unobtrusive wearable device allowing for long-term gait analysis.
Issue Date: 1-May-2018
Date of Acceptance: 12-Apr-2018
URI: http://hdl.handle.net/10044/1/59054
DOI: https://dx.doi.org/10.1016/j.gaitpost.2018.04.015
ISSN: 0966-6362
Publisher: Elsevier
Start Page: 480
End Page: 483
Journal / Book Title: Gait and Posture
Volume: 62
Copyright Statement: © 2018 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY license (http://creativecommons.org/licenses/BY/4.0/)
Sponsor/Funder: Engineering & Physical Science Research Council (EPSRC)
Funder's Grant Number: N/A
Keywords: Gait analysis
Knee kinematics
Knee monitoring
Walking
Wearable technology
1103 Clinical Sciences
1106 Human Movement And Sports Science
0913 Mechanical Engineering
Orthopedics
Publication Status: Published
Online Publication Date: 2018-04-13
Appears in Collections:Department of Surgery and Cancer