328
IRUS Total
Downloads
  Altmetric

Coherent excitation of a two-state system by a train of short pulses

File Description SizeFormat 
Coherent Excitation of A 2-State System by A Train of Short Pulses.pdfPublished version2.84 MBAdobe PDFView/Open
Title: Coherent excitation of a two-state system by a train of short pulses
Authors: VITANOV, NV
KNIGHT, PL
Item Type: Journal Article
Abstract: A theoretical nonperturbative study of the coherent excitation of a two-state system by N consecutive equally spaced identical pulses is presented. General relations between the evolution matrix elements in the cases of one and N pulses are obtained in a closed form. For pulse envelopes allowing analytical solutions, these relations enable analytical treatment of pulse-train excitation; for pulses that can only be treated numerically, they shorten the computations by a factor of N. The relations show that the multiple-pulse excitation of a two-state system can be considered as a quantum analog of the diffraction grating. The interaction dynamics substantially depends on the way the train is produced because the phase shift that is accumulated by the probability amplitudes due to the free evolution of the system during and between the pulses differs. In the limit of weak excitation, the results recover earlier conclusions based on perturbative treatments. Simple formulas are derived for the conditions for complete population inversion (CPI) and complete population return (CPR), which differ from the single-pulse ones. These general results are applied to four particular cases that allow analytical solutions: resonant, rectangular, Rosen-Zener, and Allen-Eberly pulses. A common feature in all these cases is that the number and the amplitude of oscillations in the state populations increase with the number of pulses, while their width decreases. For rectangular pulses, CPI is possible below a given value of the ratio between the detuning and the pulse area; this value increases nearly linearly with the number of pulses. For the Rosen-Zener model, CPI is found to be possible for two and more pulses, while it is impossible for a single non-resonant pulse. It is shown that for a given number of pulses there is an upper limit on the detuning for which CPI can be observed; this limit increases logarithmically with the number of pulses. For the Allen-Eberly model, CPR is established to be possible for more than one pulse, while it is impossible for a single pulse. The cases of even and odd number of pulses are shown to lead to substantially different results. The limitations imposed on the detuning by the conditions for CPR and CPI are derived and discussed.
Issue Date: 1-Sep-1995
Date of Acceptance: 28-Dec-1994
URI: http://hdl.handle.net/10044/1/388
Publisher Link: http://dx.doi.org/10.1103/PhysRevA.52.2245
DOI: 10.1103/PhysRevA.52.2245
ISSN: 1050-2947
Publisher: American Physical Society
Start Page: 2245
End Page: 2261
Journal / Book Title: Physical Review A: Atomic, Molecular and Optical Physics
Volume: 52
Issue: 3
Copyright Statement: © American Physical Society
Publication Status: Published
Appears in Collections:Quantum Optics and Laser Science
Physics
Faculty of Natural Sciences