Automated quality control in image segmentation: application to the UK Biobank cardiac MR imaging study
File(s)Robinson_Automated quality control in image_BMC.pdf (3.32 MB)
Published version
OA Location
Author(s)
Type
Journal Article
Abstract
Background: The trend towards large-scale studies including population imaging poses new challenges in terms of quality control (QC). This is a particular issue when automatic processing tools, e.g. image segmentation methods, are employed to derive quantitative measures or biomarkers for later analyses. Manual inspection and visual QC of each segmentation isn't feasible at large scale. However, it's important to be able to automatically detect when a segmentation method fails so as to avoid inclusion of wrong measurements into subsequent analyses which could lead to incorrect conclusions. Methods: To overcome this challenge, we explore an approach for predicting segmentation quality based on Reverse Classification Accuracy, which enables us to discriminate between successful and failed segmentations on a per-cases basis. We validate this approach on a new, large-scale manually-annotated set of 4,800 cardiac magnetic resonance scans. We then apply our method to a large cohort of 7,250 cardiac MRI on which we have performed manual QC. Results: We report results used for predicting segmentation quality metrics including Dice Similarity Coefficient (DSC) and surface-distance measures. As initial validation, we present data for 400 scans demonstrating 99% accuracy for classifying low and high quality segmentations using predicted DSC scores. As further validation we show high correlation between real and predicted scores and 95% classification accuracy on 4,800 scans for which manual segmentations were available. We mimic real-world application of the method on 7,250 cardiac MRI where we show good agreement between predicted quality metrics and manual visual QC scores. Conclusions: We show that RCA has the potential for accurate and fully automatic segmentation QC on a per-case basis in the context of large-scale population imaging as in the UK Biobank Imaging Study.
Date Issued
2019-03-14
Date Acceptance
2019-02-03
Citation
Journal of Cardiovascular Magnetic Resonance, 2019, 21
ISSN
1097-6647
Publisher
BioMed Central
Journal / Book Title
Journal of Cardiovascular Magnetic Resonance
Volume
21
Copyright Statement
© The Author(s). 2019Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, andreproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to theCreative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver(http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
Sponsor
Engineering & Physical Science Research Council (EPSRC)
GlaxoSmithKline
Engineering & Physical Science Research Council (EPSRC)
National Institute for Health Research
UK DRI Ltd
UK DRI Ltd
Commission of the European Communities
Innovate UK
Identifier
http://arxiv.org/abs/1901.09351v1
Grant Number
EP/N014529/1
EP/P001009/1
RDA26
N/A
N/A
H2020 - 757173
COVIP_P76965
Subjects
cs.CV
cs.CV
Notes
14 pages, 7 figures, Journal of Cardiovascular Magnetic Resonance
Publication Status
Published
Article Number
ARTN 18