Unicompartmental knee arthroplasty enables near normal gait at higher speeds, unlike total knee arthroplasty
Author(s)
Wiik, Anatole V
Manning, Victoria
Strachan, Robin K
Amis, Andrew A
Cobb, Justin Peter
Type
Journal Article
Abstract
Top walking speed (TWS) was used to compare UKA with TKA. Two groups of 23 patients, well matched for age, gender, height and weight and radiological severity were recruited based on high functional scores, more than twelve months post UKA or TKA. These were compared with 14 preop patients and 14 normal controls. Their gait was measured at increasing speeds on a treadmill instrumented with force plates. Both arthroplasty groups were significantly faster than the preop OA group. TKA patients walked substantially faster than any previously reported series of knee arthroplasties. UKA patients walked 10% faster than TKA, although not as fast as the normal controls. Stride length was 5% greater and stance time 7% shorter following UKA — both much closer to normal than TKA. Unlike TKA, UKA enables a near normal gait one year after surgery.
Date Issued
2013-10-01
Date Acceptance
2013-07-24
Citation
Journal of Arthroplasty, 2013, 28 (9), pp.176-178
ISSN
0883-5403
Publisher
Elsevier
Start Page
176
End Page
178
Journal / Book Title
Journal of Arthroplasty
Volume
28
Issue
9
Copyright Statement
© 2013 The Authors. Published by Elsevier Inc. Open access under CC BY license http://creativecommons.org/licenses/by/3.0/.
License URL
Identifier
http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=WOS:000326199600004&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=1ba7043ffcc86c417c072aa74d649202
Subjects
Science & Technology
Life Sciences & Biomedicine
Orthopedics
gait
walking speed
stride length
unicompartmental knee arthroplasty
total knee arthroplasty
REPLACEMENT
Publication Status
Published
Date Publish Online
2013-10-05