Appropriate shocks and mortality in patients with versus without diabetes with prophylactic implantable cardioverter defibrillators
File(s)Revision_cleancopy EU-CERT_DMcare.docx (40.62 KB) Fig1_EUCERT.pdf (286.45 KB)
Accepted version
Supporting information
Author(s)
Type
Journal Article
Abstract
OBJECTIVE Diabetes increases the risk of all-cause mortality and sudden cardiac death (SCD). The exact mechanisms leading to sudden death in diabetes are not well known. We compared the incidence of appropriate shocks and mortality in patients with versus without diabetes with a prophylactic implantable cardioverter defibrillator (ICD) included in the retrospective EU-CERT-ICD registry.
RESEARCH DESIGN AND METHODS AND RESULTS A total of 3,535 patients from 12 European EU-CERT-ICD centers with a mean age of 63.7 ± 11.2 years (82% males) at the time of ICD implantation were included in the analysis. A total of 995 patients (28%) had a history of diabetes. All patients had an ICD implanted for primary SCD prevention. End points were appropriate shock and all-cause mortality. Mean follow-up time was 3.2 ± 2.3 years. Diabetes was associated with a lower risk of appropriate shocks (adjusted hazard ratio [HR] 0.77 [95% CI 0.62–0.96], P = 0.02). However, patients with diabetes had significantly higher mortality (adjusted HR 1.30 [95% CI 1.11–1.53], P = 0.001).
CONCLUSIONS All-cause mortality is higher in patients with diabetes than in patients without diabetes with primary prophylactic ICDs. Subsequently, patients with diabetes have a lower incidence of appropriate ICD shocks, indicating that the excess mortality might not be caused primarily by ventricular tachyarrhythmias. These findings suggest a limitation of the potential of prophylactic ICD therapy to improve survival in patients with diabetes with impaired left ventricular function.
RESEARCH DESIGN AND METHODS AND RESULTS A total of 3,535 patients from 12 European EU-CERT-ICD centers with a mean age of 63.7 ± 11.2 years (82% males) at the time of ICD implantation were included in the analysis. A total of 995 patients (28%) had a history of diabetes. All patients had an ICD implanted for primary SCD prevention. End points were appropriate shock and all-cause mortality. Mean follow-up time was 3.2 ± 2.3 years. Diabetes was associated with a lower risk of appropriate shocks (adjusted hazard ratio [HR] 0.77 [95% CI 0.62–0.96], P = 0.02). However, patients with diabetes had significantly higher mortality (adjusted HR 1.30 [95% CI 1.11–1.53], P = 0.001).
CONCLUSIONS All-cause mortality is higher in patients with diabetes than in patients without diabetes with primary prophylactic ICDs. Subsequently, patients with diabetes have a lower incidence of appropriate ICD shocks, indicating that the excess mortality might not be caused primarily by ventricular tachyarrhythmias. These findings suggest a limitation of the potential of prophylactic ICD therapy to improve survival in patients with diabetes with impaired left ventricular function.
Date Issued
2019-10-23
Date Acceptance
2019-09-10
Citation
Diabetes Care, 2019, 42 (11)
ISSN
0149-5992
Publisher
American Diabetes Association
Journal / Book Title
Diabetes Care
Volume
42
Issue
11
Copyright Statement
© 2019 by the American Diabetes Association.
Identifier
https://care.diabetesjournals.org/content/early/2019/10/22/dc19-1014
Subjects
11 Medical and Health Sciences
Endocrinology & Metabolism
Publication Status
Published online
Date Publish Online
2019-10-23