On the Stokes number and characterization of aerosol deposition in the respiratory airways
File(s)Nicolaou_CMBE_2015.pdf (2.57 MB)
Published version
Author(s)
Nicolaou, L
Zaki, TA
Type
Conference Paper
Abstract
Aerosol deposition in the respiratory airways has traditionally been examined in terms of the Stokes number based on the reference flow timescale. This choice leads to large scatter in deposition efficiency when plotted against the reference Stokes number because the velocity and length scales experienced by advected particles deviate considerably from the reference values. A time-average of the particle local Stokes number should be adopted instead. Our results demonstrate that this average, or effective, Stokes number can deviate significantly from the reference value, in particular in the intermediate Stokes number range where variation across subjects is largest.
Date Issued
2015
Date Acceptance
2015-04-13
Citation
CMBE Proceedings, 2015, pp.224-227
ISBN
978-0-9562914-3-1
ISSN
2227-3085
Publisher
CMBE
Start Page
224
End Page
227
Journal / Book Title
CMBE Proceedings
Copyright Statement
© 2015 by the authors
Source
4th International Conference on Computational and Mathematical Biomedical Engineering - CMBE2015
Publication Status
Published
Start Date
2015-06-29
Finish Date