Hemodynamic evaluation using four-dimensional flow magnetic resonance imaging for a patient with multichanneled aortic dissection
File(s) Guo_JVS cases and innotative techniques 2018.pdf (1.97 MB)
Published version
Author(s)
Type
Journal Article
Abstract
The hemodynamic function of multichanneled aortic dissection (MCAD) requires close monitoring and effective management to avoid potentially catastrophic sequelae. This report describes a 47-year-old man who underwent endovascular repair based on findings from four-dimensional (4D) flow magnetic resonance imaging of an MCAD. The acquired 4D flow data revealed complex, bidirectional flow patterns in the false lumens and accelerated blood flow in the compressed true lumen. The collapsed abdominal true lumen expanded unsatisfactorily after primary tear repair, which required further remodeling with bare stents. This case study demonstrates that hemodynamic analysis using 4D flow magnetic resonance imaging can help understand the complex pathologic changes of MCAD.
Date Issued
2018-03-01
Date Acceptance
2017-11-11
Citation
Journal of Vascular Surgery Cases and Innovative Techniques, 2018, 4 (1), pp.67-71
ISSN
2468-4287
Publisher
Elsevier
Start Page
67
End Page
71
Journal / Book Title
Journal of Vascular Surgery Cases and Innovative Techniques
Volume
4
Issue
1
Copyright Statement
Crown Copyright © 2017 Published by Elsevier Inc. on behalf of Society for Vascular Surgery. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
Publication Status
Published