Repository logo
  • Log In
    Log in via Symplectic to deposit your publication(s).
Repository logo
  • Communities & Collections
  • Research Outputs
  • Statistics
  • Log In
    Log in via Symplectic to deposit your publication(s).
  1. Home
  2. Faculty of Engineering
  3. Mechanical Engineering
  4. Mechanical Engineering
  5. Towards a commercial system for intraoperative manufacture of patient-specific guides for shoulder arthroplasty
 
  • Details
Towards a commercial system for intraoperative manufacture of patient-specific guides for shoulder arthroplasty
File(s)
Towards_a_Commercial_System_for_Intraoperative_Manufacture_of_Patient-Specific_Guides_for_Shoulder_Arthroplasty.pdf (4.17 MB)
Published version
OA Location
https://easychair.org/publications/open/rH7J
Author(s)
Darwood, Alastair
Hurst, Simon
Villatte, Guillaume
Fenton, Ryan
Tatti, Fabio
more
Type
Conference Paper
Abstract
The accurate placement of orthopaedic implants according to a biomechanically derived preoperative plan is an important consideration in the long-term success of these interventions. Guidance technologies are widely described however, high cost, complex theatre integration, intraoperative inefficiency and functional limitations have prevented the widespread use. A novel, intraoperative mechatronics platform is presented, capable of the rapid, intraoperative manufacture of low-cost patient-specific guides. The device consists of a tableside robot with sterile drapes and some low cost, sterile disposable components. The robot comprises a 3D optical scanner, a three-axis sterile computer numerical control (CNC) drill and a two-axis receptacle into which the disposable consumables may be inserted. The sterile consumable comprises a region of rapidly setting moldable material and a clip allowing it to be reversibly attached to the tableside robot. In use, patient computed tomography (CT) imaging is obtained at any point prior to surgery and a surgical plan is created on associated software. This plan describes the axis and positioning of one or more guidewires which may, in turn, locate the prosthesis into position. Intraoperatively, osseous anatomy is exposed, and the sterile disposable is used to rapidly create a mould of the joint surface. Once set, the mould is inserted into the robot and an optical scan of the surface is taken followed by automatic surface registration, bringing the optical scan into the same coordinate frame of reference as the CT data and plan. The CNC drill is orientated such that the drill axis and position exactly matches the planned axis and position with respect to the moulded surface. A guide hole is drilled into the mould blank, which is removed from the robot and placed back into the patient with the moulded surface ensuring exact replacement. A wire is subsequently driven through the guide hole into the osseous anatomy in accordance with the preoperative plan. The guide blank may be slid off the wire and discarded allowing the procedure to continue in the normal manner. A Pre-clinical prototype robot was constructed and used to insert guide wires into a 12 cadaveric shoulder arthroplasty specimens according to a ‘pre-operative’ plan. A ‘postoperative’ CT scan was used to assess accuracy with respect to the ‘pre-operative’ plan. Initial average end to end accuracy was 1.2 mm with respect to planned vs achieved glenoid point of entry and 2.2deg version, 1.6deg inclination with respect to planned vs achieved wire angle. These data demonstrate accuracy within the bounds of relevant literature with a significant margin for potential improvement.
Date Acceptance
2019-06-01
Citation
3, pp.110-114
URI
http://hdl.handle.net/10044/1/79743
URL
https://easychair.org/publications/paper/rH7J
DOI
https://www.dx.doi.org/10.29007/wkh3
Publisher
EasyChair
Start Page
110
End Page
114
Volume
3
Copyright Statement
© 2019 The Author(s).
Identifier
https://easychair.org/publications/paper/rH7J
Source
CAOS 2019. The 19th Annual Meeting of the International Society for Computer Assisted Orthopaedic Surgery
Publication Status
Published
Start Date
2019-06-19
Finish Date
2019-06-22
Coverage Spatial
New York, USA
Date Publish Online
2019-10-26
About
Spiral Depositing with Spiral Publishing with Spiral Symplectic
Contact us
Open access team Report an issue
Other Services
Scholarly Communications Library Services
logo

Imperial College London

South Kensington Campus

London SW7 2AZ, UK

tel: +44 (0)20 7589 5111

Accessibility Modern slavery statement Cookie Policy

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback