Quantifying coal power plant responses to tighter SO₂ emissions standards in China
Author(s)
Karplus, Valerie J
Zhang, Shuang
Almond, Douglas
Type
Journal Article
Abstract
Significance
We observe large reductions in the concentration of sulfur dioxide (SO2) from coal power plants in China following the implementation of a tougher national air emissions standard using a high-frequency plant-level data source. We find a corresponding decline in SO2 measures in satellite observations. However, correspondence between these two measures is lower in areas that faced a sharper increase in standard stringency.
Abstract
We evaluate the impact of China’s new air pollution standards on sulfur dioxide (SO2) emissions by comparing newly available data from Continuous Emissions Monitoring Systems (CEMS) at coal power plants with satellite measures. First, we show that following the July 2014 deadline for implementing tighter emissions standards, stack concentrations of SO2 reported by CEMS declined by 13.9%. Second, on average the ratios of the declines of SO2 measures in the satellite data and the CEMS data are about 0.5. However, the degree of correspondence between the two data sources varies by policy stringency, with weak correspondence found in key regions facing the toughest new limits. Third, large plants achieved compliance earlier than small (typically) power and heat cogeneration plants. To achieve continued air quality improvement, our results suggest a need for increased scrutiny of emissions data quality and monitoring practices and clear long-term targets.
We observe large reductions in the concentration of sulfur dioxide (SO2) from coal power plants in China following the implementation of a tougher national air emissions standard using a high-frequency plant-level data source. We find a corresponding decline in SO2 measures in satellite observations. However, correspondence between these two measures is lower in areas that faced a sharper increase in standard stringency.
Abstract
We evaluate the impact of China’s new air pollution standards on sulfur dioxide (SO2) emissions by comparing newly available data from Continuous Emissions Monitoring Systems (CEMS) at coal power plants with satellite measures. First, we show that following the July 2014 deadline for implementing tighter emissions standards, stack concentrations of SO2 reported by CEMS declined by 13.9%. Second, on average the ratios of the declines of SO2 measures in the satellite data and the CEMS data are about 0.5. However, the degree of correspondence between the two data sources varies by policy stringency, with weak correspondence found in key regions facing the toughest new limits. Third, large plants achieved compliance earlier than small (typically) power and heat cogeneration plants. To achieve continued air quality improvement, our results suggest a need for increased scrutiny of emissions data quality and monitoring practices and clear long-term targets.
Date Issued
2018-07-03
Date Acceptance
2018-05-08
Citation
Proceedings of the National Academy of Sciences of USA, 2018, 115 (27), pp.7004-7009
ISSN
0027-8424
Publisher
National Academy of Sciences
Start Page
7004
End Page
7009
Journal / Book Title
Proceedings of the National Academy of Sciences of USA
Volume
115
Issue
27
Copyright Statement
Copyright © 2018 the Author(s). Published by PNAS. This open access article is distributed under Creative Commons Attribution-NonCommercial-NoDerivatives License 4.0 (CC BY-NC-ND).
Identifier
http://dx.doi.org/10.1073/pnas.1800605115
Publication Status
Published
Date Publish Online
2018-06-18