Greenhouse gas emissions associated with suboptimal asthma care in the UK: the SABINA healthCARe-Based envirONmental cost of treatment (CARBON) study
File(s)412.full.pdf (1.79 MB)
Published version
Author(s)
Wilkinson, Alexander JK
Maslova, Ekaterina
Janson, Christer
Radhakrishnan, Vasanth
Quint, Jennifer K
Type
Journal Article
Abstract
BACKGROUND: Poorly controlled asthma is associated with increased morbidity and healthcare resource utilisation (HCRU). Therefore, to quantify the environmental impact of asthma care, this retrospective, cohort, healthCARe-Based envirONmental cost of treatment (CARBON) study estimated greenhouse gas (GHG) emissions in the UK associated with the management of well-controlled versus poorly controlled asthma. METHODS: Patients with current asthma (aged ≥12 years) registered with the Clinical Practice Research Datalink (2008‒2019) were included. GHG emissions, measured as carbon dioxide equivalent (CO2e), were estimated for asthma-related medication use, HCRU and exacerbations during follow-up of patients with asthma classified at baseline as well-controlled (<3 short-acting β2-agonist (SABA) canisters/year and no exacerbations) or poorly controlled (≥3 SABA canisters/year or ≥1 exacerbation). Excess GHG emissions due to suboptimal asthma control included ≥3 SABA canister prescriptions/year, exacerbations and any general practitioner and outpatient visits within 10 days of hospitalisation or an emergency department visit. RESULTS: Of the 236 506 patients analysed, 47.3% had poorly controlled asthma at baseline. Scaled to the national level, the overall carbon footprint of asthma care in the UK was 750 540 tonnes CO2e/year, with poorly controlled asthma contributing excess GHG emissions of 303 874 tonnes CO2e/year, which is equivalent to emissions from >124 000 houses in the UK. Poorly controlled versus well-controlled asthma generated 3.1-fold higher overall and 8.1-fold higher excess per capita carbon footprint, largely SABA-induced, with smaller contributions from HCRU. CONCLUSIONS: These findings suggest that addressing the high burden of poorly controlled asthma, including curbing high SABA use and its associated risk of exacerbations, may significantly alleviate asthma care-related carbon emissions.
Date Issued
2024-04-15
Date Acceptance
2023-11-17
Citation
Thorax, 2024, 79 (5), pp.412-421
ISSN
0040-6376
Publisher
BMJ Publishing Group
Start Page
412
End Page
421
Journal / Book Title
Thorax
Volume
79
Issue
5
Copyright Statement
© Author(s) (or their employer(s)) 2024. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. http://creativecommons.org/licenses/by-nc/4.0/
This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/.
This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/.
License URL
Identifier
https://www.ncbi.nlm.nih.gov/pubmed/38413192
Subjects
asthma
inhaler devices
Publication Status
Published
Coverage Spatial
England
Date Publish Online
2024-02-27