Operating characteristics and performance improvements of a 500 W traveling-wave thermoacoustic electric generator
Author(s)
Type
Journal Article
Abstract
Traveling-wave thermoacoustic electric generator has drawn increasing attention due to its great prospect in energy conversion. In this work, a traveling-wave thermoacoustic electric generator capable of generating about 500 W electric power is studied numerically and experimentally. The performances and the operating characteristics of the system under different working conditions are tested and analyzed. The maximum electric powers can be obtained with electric load resistance around 100–120 Ω, and the highest thermal-to-electric efficiencies can be achieved at much larger load resistances. The efficiency at low load resistance is relatively small due to the large pressure amplitudes inside the thermoacoustic system, which increases the dissipations. The variation trends of the electric power and the thermal-to-electric efficiency with the load resistance intrinsically result from the changes of the corresponding acoustic impedance of the linear alternators, which determines the output performance of the thermoacoustic engine meanwhile. The distributions of the acoustic power losses are then calculated and firstly illustrated quantitatively. It is shown that the resonator causes most of the acoustic power losses, and the losses in hot heat exchanger, thermal buffer tube, and feedback tube are also significant. The output performance of the system can be improved by increasing the heating temperature and the mean pressure. A maximum electric power of 473.6 W and a highest thermal-to-electric efficiency of 14.5% are achieved experimentally when the mean pressure is 2.48 MPa and the heating temperature is 650 °C. A pair of linear alternators with a larger swept volume and appropriate acoustic impedances is finally designed to couple with the thermoacoustic torus directly. Numerical results show that the maximum electric power can be increased to 718 W and 1005 W when the mean pressures are kept at 2.48 MPa and 3.20 MPa, corresponding to the improvements of 42.6% and 29.4% compared with those of the original system.
Date Issued
2015-12-15
Date Acceptance
2015-03-17
Citation
Applied Energy, 2015, 160, pp.853-862
ISSN
0306-2619
Publisher
Elsevier
Start Page
853
End Page
862
Journal / Book Title
Applied Energy
Volume
160
Copyright Statement
© 2015 Elsevier Ltd. All rights reserved. This manuscript is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International http://creativecommons.org/licenses/by-nc-nd/4.0/
Identifier
http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=WOS:000364890700083&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=1ba7043ffcc86c417c072aa74d649202
Subjects
Science & Technology
Technology
Energy & Fuels
Engineering, Chemical
Engineering
Thermoacoustic
Electric generation
Linear alternator
Acoustic power
HEAT ENGINE
STIRLING ENGINES
ENERGY
Publication Status
Published
Date Publish Online
2015-04-01