Interlaboratory reproducibility of a targeted metabolomics platform for analysis of human serum and plasma
File(s)AP_Siskos_et_al_manuscript_2016_nov.docx (864.58 KB)
Accepted version
Author(s)
Type
Journal Article
Abstract
A critical question facing the field of metabolomics is whether data obtained from different centers can be effectively compared and combined. An important aspect of this is the interlaboratory precision (reproducibility) of the analytical protocols used. We analyzed human samples in six laboratories using different instrumentation but a common protocol (the AbsoluteIDQ p180 kit) for the measurement of 189 metabolites via liquid chromatography (LC) or flow injection analysis (FIA) coupled to tandem mass spectrometry (MS/MS). In spiked quality control (QC) samples 82% of metabolite measurements had an interlaboratory precision of <20%, while 83% of averaged individual laboratory measurements were accurate to within 20%. For 20 typical biological samples (serum and plasma from healthy individuals) the median interlaboratory coefficient of variation (CV) was 7.6%, with 85% of metabolites exhibiting a median interlaboratory CV of <20%. Precision was largely independent of the type of sample (serum or plasma) or the anticoagulant used but was reduced in a sample from a patient with dyslipidaemia. The median interlaboratory accuracy and precision of the assay for standard reference plasma (NIST SRM 1950) were 107% and 6.7%, respectively. Likely sources of irreproducibility were the near limit of detection (LOD) typical abundance of some metabolites and the degree of manual review and optimization of peak integration in the LC–MS/MS data after acquisition. Normalization to a reference material was crucial for the semi-quantitative FIA measurements. This is the first interlaboratory assessment of a widely used, targeted metabolomics assay illustrating the reproducibility of the protocol and how data generated on different instruments could be directly integrated in large-scale epidemiological studies.
Date Issued
2016-11-30
Date Acceptance
2016-11-30
Citation
Analytical Chemistry, 2016, 89 (1), pp.656-665
ISSN
1086-4377
Publisher
American Chemical Society
Start Page
656
End Page
665
Journal / Book Title
Analytical Chemistry
Volume
89
Issue
1
Copyright Statement
© 2016 American Chemical Society. This document is the Accepted Manuscript version of a Published Work that appeared in final form in Analytical Chemistry, copyright © American Chemical Society after peer review and technical editing by the publisher. To access the final edited and published work see http://dx.doi.org/10.1021/acs.analchem.6b02930
Sponsor
Commission of the European Communities
Commission of the European Communities
Identifier
http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=WOS:000391346600050&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=1ba7043ffcc86c417c072aa74d649202
Grant Number
259867
308333
Subjects
Science & Technology
Physical Sciences
Chemistry, Analytical
Chemistry
STANDARD REFERENCE MATERIAL
NMR
COHORT
METABOLISM
BIOMARKERS
CANCERS
Analytical Chemistry
0301 Analytical Chemistry
0904 Chemical Engineering
0399 Other Chemical Sciences
Publication Status
Published