Valvular and perivalvular thrombosis following self-expandable aortic valve replacement: analysis of 100 multi-detector computed tomography scans
File(s) oeae085.pdf (1.23 MB)
Published version
Author(s)
Type
Journal Article
Abstract
Aims
Subclinical thrombosis may represent an early stage of prosthesis structural disease. Most of the available evidence on the incidence, location, predictors, and consequences of thrombosis comes from studies that have employed balloon-expandable valves. We aimed to describe the different localisations of valvular and perivalvular thrombosis and analyse prosthesis-host multi-detector computed tomography predictors in the context of self-expandable prosthesis. Additionally, we aimed to assess the impact of valvular and perivalvular thrombosis on prosthesis performance and subsequent clinical outcomes.
Methods and results
This analysis includes 100 consecutive patients with normal renal function who underwent transcatheter aortic valve replacement using Evolut R and received multi-detector computed tomography and transthoracic bi-dimensional echocardiography at the 6 month follow-up. Leaflet thrombosis was detected in 18 (18%) patients; 6 (6%) had at least one leaflet with severe thrombosis. Thrombosis of the anatomic sinus was detected in 24 patients (24%) and was more prevalent in the non-coronary sinus. Subvalvular thrombosis with partial or complete circumferential involvement of the prosthesis inner skirt was diagnosed in 23 patients (23%). Bicuspid valve was the predictor with highest association with hypoattenuated lesions [least absolute shrinkage and selection operator coefficient 0.35, 95%, confidence interval (CI) 0.21–0.68]. There was no difference in terms of haemodynamic structural valve dysfunction, neurological events, and re-hospitalisation between the groups with and without thrombosis (hazard ratio: 0.86, 95% CI: 0.24–3.06, P = 0.82).
Conclusion
This study showed that in a relatively low-risk population, valvular and perivalvular thrombosis were not rare phenomena following transcatheter aortic valve replacement at early follow-up. Bicuspid valve showed the strongest association with post-implant thrombosis.
Subclinical thrombosis may represent an early stage of prosthesis structural disease. Most of the available evidence on the incidence, location, predictors, and consequences of thrombosis comes from studies that have employed balloon-expandable valves. We aimed to describe the different localisations of valvular and perivalvular thrombosis and analyse prosthesis-host multi-detector computed tomography predictors in the context of self-expandable prosthesis. Additionally, we aimed to assess the impact of valvular and perivalvular thrombosis on prosthesis performance and subsequent clinical outcomes.
Methods and results
This analysis includes 100 consecutive patients with normal renal function who underwent transcatheter aortic valve replacement using Evolut R and received multi-detector computed tomography and transthoracic bi-dimensional echocardiography at the 6 month follow-up. Leaflet thrombosis was detected in 18 (18%) patients; 6 (6%) had at least one leaflet with severe thrombosis. Thrombosis of the anatomic sinus was detected in 24 patients (24%) and was more prevalent in the non-coronary sinus. Subvalvular thrombosis with partial or complete circumferential involvement of the prosthesis inner skirt was diagnosed in 23 patients (23%). Bicuspid valve was the predictor with highest association with hypoattenuated lesions [least absolute shrinkage and selection operator coefficient 0.35, 95%, confidence interval (CI) 0.21–0.68]. There was no difference in terms of haemodynamic structural valve dysfunction, neurological events, and re-hospitalisation between the groups with and without thrombosis (hazard ratio: 0.86, 95% CI: 0.24–3.06, P = 0.82).
Conclusion
This study showed that in a relatively low-risk population, valvular and perivalvular thrombosis were not rare phenomena following transcatheter aortic valve replacement at early follow-up. Bicuspid valve showed the strongest association with post-implant thrombosis.
Editor(s)
Flachskampf, Frank A
Date Issued
2024-09-01
Date Acceptance
2024-09-13
Citation
European Heart Journal Open, 2024, 4 (5)
ISSN
2752-4191
Publisher
Oxford University Press
Journal / Book Title
European Heart Journal Open
Volume
4
Issue
5
Copyright Statement
© The Author(s) 2024. Published by Oxford University Press on behalf of the European Society of Cardiology. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited.
License URL
Identifier
https://www.ncbi.nlm.nih.gov/pubmed/39687471
PII: oeae085
Subjects
Hypoattenuated lesion
Multi-detector computed tomography
Subclinical leaflet thrombosis
Transcatheter aortic valve replacement
Publication Status
Published
Coverage Spatial
England
Article Number
oeae085
Date Publish Online
2024-10-15
