Background
Bazett formula is frequently used in paediatric screening for the long QT syndrome (LQTS) and proposals exist that using standing rather than supine electrocardiograms (ECG) improves the sensitivity of LQTS diagnosis. Nevertheless, compared to adults, children have higher heart rates (especially during postural provocations) and Bazett correction is also known to lead to artificially prolonged QTc values at increased heart rates. This study assessed the incidence of erroneously increased QTc values in normal children without QT abnormalities.
Methods
Continuous 12-lead ECGs were recorded in 332 healthy children (166 girls) aged 10.7 ± 2.6 years while they performed postural manoeuvring consisting of episodes (in the following order) of supine, sitting, standing, supine, standing, sitting, and supine positions, each lasting 10 min. Detailed analyses of QT/RR profiles confirmed the absence of prolonged individually corrected QTc interval in each child. Heart rate and QT intervals were measured in 10-s ECG segments and in each segment, QTc intervals were obtained using Bazett, Fridericia, and Framingham formulas. In each child, the heart rates and QTc values obtained during supine, sitting and standing positions were averaged. QTc durations by the three formulas were classified to < 440 ms, 440–460 ms, 460–480 ms, and > 480 ms.
Results
At supine position, averaged heart rate was 77.5 ± 10.5 beat per minute (bpm) and Bazett, Fridericia and Framingham QTc intervals were 425.3 ± 15.8, 407.8 ± 13.9, and 408.2 ± 13.1 ms, respectively. At sitting and standing, averaged heart rate increased to 90.9 ± 10.1 and 100.9 ± 10.5 bpm, respectively. While Fridericia and Framingham formulas showed only minimal QTc changes, Bazett correction led to QTc increases to 435 ± 15.1 and 444.9 ± 15.9 ms at sitting and standing, respectively. At sitting, Bazett correction identified 51, 4, and 0 children as having the QTc intervals 440–460, 460–480, and > 480 ms, respectively. At sitting, these numbers increased to 118, 11, and 1, while on standing these numbers were 151, 45, and 5, respectively. Irrespective of the postural position, Fridericia and Framingham formulas identified only a small number (< 7) of children with QT interval between 440 and 460 ms and no children with longer QTc.
Conclusion
During screening for LQTS in children, the use of Bazett formula leads to a high number of false positive cases especially if the heart rates are increased (e.g. by postural manoeuvring). The use of Fridericia formula can be recommended to replace the Bazett correction not only for adult but also for paediatric ECGs.
Bazett formula is frequently used in paediatric screening for the long QT syndrome (LQTS) and proposals exist that using standing rather than supine electrocardiograms (ECG) improves the sensitivity of LQTS diagnosis. Nevertheless, compared to adults, children have higher heart rates (especially during postural provocations) and Bazett correction is also known to lead to artificially prolonged QTc values at increased heart rates. This study assessed the incidence of erroneously increased QTc values in normal children without QT abnormalities.
Methods
Continuous 12-lead ECGs were recorded in 332 healthy children (166 girls) aged 10.7 ± 2.6 years while they performed postural manoeuvring consisting of episodes (in the following order) of supine, sitting, standing, supine, standing, sitting, and supine positions, each lasting 10 min. Detailed analyses of QT/RR profiles confirmed the absence of prolonged individually corrected QTc interval in each child. Heart rate and QT intervals were measured in 10-s ECG segments and in each segment, QTc intervals were obtained using Bazett, Fridericia, and Framingham formulas. In each child, the heart rates and QTc values obtained during supine, sitting and standing positions were averaged. QTc durations by the three formulas were classified to < 440 ms, 440–460 ms, 460–480 ms, and > 480 ms.
Results
At supine position, averaged heart rate was 77.5 ± 10.5 beat per minute (bpm) and Bazett, Fridericia and Framingham QTc intervals were 425.3 ± 15.8, 407.8 ± 13.9, and 408.2 ± 13.1 ms, respectively. At sitting and standing, averaged heart rate increased to 90.9 ± 10.1 and 100.9 ± 10.5 bpm, respectively. While Fridericia and Framingham formulas showed only minimal QTc changes, Bazett correction led to QTc increases to 435 ± 15.1 and 444.9 ± 15.9 ms at sitting and standing, respectively. At sitting, Bazett correction identified 51, 4, and 0 children as having the QTc intervals 440–460, 460–480, and > 480 ms, respectively. At sitting, these numbers increased to 118, 11, and 1, while on standing these numbers were 151, 45, and 5, respectively. Irrespective of the postural position, Fridericia and Framingham formulas identified only a small number (< 7) of children with QT interval between 440 and 460 ms and no children with longer QTc.
Conclusion
During screening for LQTS in children, the use of Bazett formula leads to a high number of false positive cases especially if the heart rates are increased (e.g. by postural manoeuvring). The use of Fridericia formula can be recommended to replace the Bazett correction not only for adult but also for paediatric ECGs.
Date Issued
2020-12-14
Date Acceptance
2020-12-08
Citation
BMC Pediatrics, 2020, 20 (1)
ISSN
1471-2431
Publisher
BioMed Central
Journal / Book Title
BMC Pediatrics
Volume
20
Issue
1
Copyright Statement
© The Author(s). 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License,
which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give
appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if
changes were made. The images or other third party material in this article are included in the article's Creative Commons
licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons
licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain
permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the
data made available in this article, unless otherwise stated in a credit line to the data.
which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give
appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if
changes were made. The images or other third party material in this article are included in the article's Creative Commons
licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons
licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain
permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the
data made available in this article, unless otherwise stated in a credit line to the data.
License URL
Sponsor
British Heart Foundation
Grant Number
NH/16/2/32499
Subjects
1114 Paediatrics and Reproductive Medicine
Pediatrics
Publication Status
Published
Article Number
558
Date Publish Online
2020-12-14