Attenuation of reflected waves in man during retrograde propagation from femoral artery to proximal aorta
File(s)Baksi_Wave reflection_2-jhs-forspiral.pdf (155.02 KB)
Accepted version
Author(s)
Type
Journal Article
Abstract
Background
Wave reflection may be an important influence on blood pressure, but the extent to which reflections undergo attenuation during retrograde propagation has not been studied. We quantified retrograde transmission of a reflected wave created by occlusion of the left femoral artery in man.
Methods
20 subjects (age 31–83 years; 14 male) underwent invasive measurement of pressure and flow velocity with a sensor-tipped intra-arterial wire at multiple locations distal to the proximal aorta before, during and following occlusion of the left femoral artery by thigh cuff inflation. A numerical model of the circulation was also used to predict reflected wave transmission. Wave reflection was measured as the ratio of backward to forward wave energy (WRI) and the ratio of peak backward to forward pressure (Pb/Pf).
Results
Cuff inflation caused a marked reflection which was largest at 5–10 cm from the cuff (change (Δ) in WRI = 0.50 (95% CI 0.38, 0.62); p < 0.001, ΔPb/Pf = 0.23 (0.18–0.29); p < 0.001). The magnitude of the cuff-induced reflection decreased progressively at more proximal locations and was barely discernible at sites > 40 cm from the cuff including in the proximal aorta. Numerical modelling gave similar predictions to those observed experimentally.
Conclusions
Reflections due to femoral artery occlusion are markedly attenuated by the time they reach the proximal aorta. This is due to impedance mismatches of bifurcations traversed in the backward direction. This degree of attenuation is inconsistent with the idea of a large discrete reflected wave arising from the lower limb and propagating back into the aorta.
Wave reflection may be an important influence on blood pressure, but the extent to which reflections undergo attenuation during retrograde propagation has not been studied. We quantified retrograde transmission of a reflected wave created by occlusion of the left femoral artery in man.
Methods
20 subjects (age 31–83 years; 14 male) underwent invasive measurement of pressure and flow velocity with a sensor-tipped intra-arterial wire at multiple locations distal to the proximal aorta before, during and following occlusion of the left femoral artery by thigh cuff inflation. A numerical model of the circulation was also used to predict reflected wave transmission. Wave reflection was measured as the ratio of backward to forward wave energy (WRI) and the ratio of peak backward to forward pressure (Pb/Pf).
Results
Cuff inflation caused a marked reflection which was largest at 5–10 cm from the cuff (change (Δ) in WRI = 0.50 (95% CI 0.38, 0.62); p < 0.001, ΔPb/Pf = 0.23 (0.18–0.29); p < 0.001). The magnitude of the cuff-induced reflection decreased progressively at more proximal locations and was barely discernible at sites > 40 cm from the cuff including in the proximal aorta. Numerical modelling gave similar predictions to those observed experimentally.
Conclusions
Reflections due to femoral artery occlusion are markedly attenuated by the time they reach the proximal aorta. This is due to impedance mismatches of bifurcations traversed in the backward direction. This degree of attenuation is inconsistent with the idea of a large discrete reflected wave arising from the lower limb and propagating back into the aorta.
Date Issued
2015-09-28
Date Acceptance
2015-09-21
Citation
International Journal of Cardiology, 2015, 202, pp.441-445
ISSN
1874-1754
Publisher
Elsevier
Start Page
441
End Page
445
Journal / Book Title
International Journal of Cardiology
Volume
202
Copyright Statement
© 2015, Elsevier. Licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International http://creativecommons.org/licenses/by-nc-nd/4.0/
Subjects
Wave reflection
Blood pressure
Hemodynamics
Publication Status
Published