  5. In situ observation and analysis of ultrasonic capillary effect in molten aluminium
 
  • Details
In situ observation and analysis of ultrasonic capillary effect in molten aluminium
File(s)
1-s2.0-S1350417715001224-main.pdf (3.2 MB)
Published version
OA Location
http://dx.doi.org/10.1016/j.ultsonch.2015.04.029
Author(s)
Tzanakis, I
Xu, WW
Eskin, DG
Lee, PD
Kotsovinos, N
Type
Journal Article
Abstract
An in situ synchrotron radiographic study of a molten Al–10 wt% Cu alloy under the influence of an external ultrasonic field was carried out using the Diamond-Manchester Branchline pink X-ray imaging at the Diamond Light Source in UK. A bespoke test rig was used, consisting of an acoustic transducer with a titanium sonotrode coupled with a PID-controlled resistance furnace. An ultrasonic frequency of 30 kHz, with a peak to peak amplitude at 140 microns, was used, producing a pressure output of 16.9 MPa at the radiation surface of the 1-mm diameter sonotrode.

This allowed quantification of not only the cavitation bubble formation and collapse, but there was also evidence of the previously hypothesised ultrasonic capillary effect (UCE), providing the first direct observations of this phenomenon in a molten metallic alloy. This was achieved by quantifying the re-filling of a pre-existing groove in the shape of a tube (which acted as a micro-capillary channel) formed by the oxide envelope of the liquid sample. Analytical solutions of the flow suggest that the filling process, which took place in very small timescales, was related to micro-jetting from the collapsing cavitation bubbles. In addition, a secondary mechanism of liquid penetration through the groove, which is related with the density distribution of the oxides inside the groove, and practically to the filtration of aluminium melt from oxides, was revealed. The observation of the almost instantaneous re-filling of a micro-capillary channel with the metallic melt supports the hypothesised sono-capillary effect in technologically important liquids other than water, like metallic alloys with substantially higher surface tension and density.
Date Issued
2015-05-06
Date Acceptance
2015-04-20
Citation
Ultrasonics Sonochemistry, 2015, 27, pp.72-80
URI
http://hdl.handle.net/10044/1/33886
DOI
https://www.dx.doi.org/10.1016/j.ultsonch.2015.04.029
ISSN
1873-2828
Publisher
Elsevier
Start Page
72
End Page
80
Journal / Book Title
Ultrasonics Sonochemistry
Volume
27
Copyright Statement
Crown Copyright © 2015 Published by Elsevier B.V. This is an open access article under the CC BY license
(http://creativecommons.org/licenses/by/4.0/).
License URL
http://creativecommons.org/licenses/by/4.0/
Sponsor
Engineering & Physical Science Research Council (E
Grant Number
EP/I021566/1
Subjects
Science & Technology
Technology
Physical Sciences
Acoustics
Chemistry, Multidisciplinary
Chemistry
Sono-capillary
Liquid metal
Cavitation
Micro jet
Oxide
Melt-filtration
CAVITATION BUBBLES
ACOUSTIC CAVITATION
FILTRATION
PRESSURE
COLLAPSE
ALLOYS
Organic Chemistry
0306 Physical Chemistry (Incl. Structural)
Publication Status
Published
About
Spiral Depositing with Spiral Publishing with Spiral Symplectic
Contact us
Open access team Report an issue
Other Services
Scholarly Communications Library Services
logo

Imperial College London

South Kensington Campus

London SW7 2AZ, UK

tel: +44 (0)20 7589 5111

Accessibility Modern slavery statement Cookie Policy

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback