Use of oscillatory positive expiratory pressure (OPEP) devices to augment sputum clearance in COPD: a systematic review and meta-analysis
File(s)Acapella review uploaded 19-6-20.docx (166.52 KB)
Accepted version
Author(s)
Type
Journal Article
Abstract
Introduction: Oscillating positive expiratory pressure (OPEP) devices are intended to facilitate sputum clearance in COPD, but there is uncertainty as to their place in treatment pathways. We aimed to review the existing literature to establish the evidence base for their use.
Methods: A systematic search of records up to March 2020 was performed on PubMed, CINAHL, Medline (Ovid), Cochrane, and Embase to retrieve clinical trials that evaluated the efficacy of OPEP devices in patients with COPD. Two independent reviewers retrieved the titles, abstracts, and full texts, and completed the data extraction.
Results: Following full text review of 77 articles, 8 (six randomised control trials and two crossover studies) were eligible for inclusion. Pooled analysis showed low grade evidence that the use of OPEP devices was associated with decreased COPD symptoms and exacerbations (odds ratio [95% CI], 0.37 [0.19 to 0.72]), and enhanced exercise capacity; 6 minute walk distance (mean difference [95% CI], 49.8m [14.2m to 85.5m]; p=0.009]). However, studies were mostly short term with the majority having a high risk of bias. The average acceptance, completion, and dropout rates were 82%, 91%, and 8%, respectively.
Conclusion: The use of OPEP devices can have a positive impact in COPD, but effect sizes are small and there is a need for further, higher quality studies to examine their long-term efficacy in COPD as well as to identify specific patient phenotypes that are more likely to respond.
Methods: A systematic search of records up to March 2020 was performed on PubMed, CINAHL, Medline (Ovid), Cochrane, and Embase to retrieve clinical trials that evaluated the efficacy of OPEP devices in patients with COPD. Two independent reviewers retrieved the titles, abstracts, and full texts, and completed the data extraction.
Results: Following full text review of 77 articles, 8 (six randomised control trials and two crossover studies) were eligible for inclusion. Pooled analysis showed low grade evidence that the use of OPEP devices was associated with decreased COPD symptoms and exacerbations (odds ratio [95% CI], 0.37 [0.19 to 0.72]), and enhanced exercise capacity; 6 minute walk distance (mean difference [95% CI], 49.8m [14.2m to 85.5m]; p=0.009]). However, studies were mostly short term with the majority having a high risk of bias. The average acceptance, completion, and dropout rates were 82%, 91%, and 8%, respectively.
Conclusion: The use of OPEP devices can have a positive impact in COPD, but effect sizes are small and there is a need for further, higher quality studies to examine their long-term efficacy in COPD as well as to identify specific patient phenotypes that are more likely to respond.
Date Issued
2020-09-15
Date Acceptance
2020-06-19
Citation
Thorax, 2020, 75, pp.855-863
ISSN
0040-6376
Publisher
BMJ Publishing Group
Start Page
855
End Page
863
Journal / Book Title
Thorax
Volume
75
Copyright Statement
© Author(s) (or their employer(s)) 2020. No commercial re-use. See rights and permissions. Published by BMJ.
Sponsor
Saudi Arabian Cultural Bureau
Saudi Arabian Cultural Bureau
Saudi Arabian Cultural Bureau
Grant Number
n/a
TAU695
Subjects
COPD exacerbations
exercise
pulmonary rehabilitation
Respiratory System
1103 Clinical Sciences
Publication Status
Published
Date Publish Online
2020-08-11