Stable distance regression via spatial–frequency state space model for robot-assisted endomicroscopy
File(s) s11548-025-03353-w.pdf (921.93 KB)
Published version
Author(s)
Zhou, Mengyi
Xu, Chi
Giannarou, Stamatia
Type
Journal Article
Abstract
Purpose
Probe-based confocal laser endomicroscopy (pCLE) is a noninvasive technique that enables the direct visualization of tissue at a microscopic level in real time. One of the main challenges in using pCLE is maintaining the probe within a working range of micrometer scale. As a result, the need arises for automatically regressing the probe–tissue distance to enable precise robotic tissue scanning.
Methods
In this paper, we propose the spatial frequency bidirectional structured state space model (SF-BiS4D) for pCLE probe–tissue distance regression. This model advances traditional state space models by processing image sequences bidirectionally and analyzing data in both the frequency and spatial domains. Additionally, we introduce a guided trajectory planning strategy that generates pseudo-distance labels, facilitating the training of sequential models to generate smooth and stable robotic scanning trajectories. To improve inference speed, we also implement a hierarchical guided fine-tuning (GF) approach that efficiently reduces the size of the BiS4D model while maintaining performance.
Results
The performance of our proposed model has been evaluated both qualitatively and quantitatively using the pCLE regression dataset (PRD). In comparison with existing state-of-the-art (SOTA) methods, our approach demonstrated superior performance in terms of accuracy and stability.
Conclusion
Our proposed deep learning-based framework effectively improves distance regression for microscopic visual servoing and demonstrates its potential for integration into surgical procedures requiring precise real-time intraoperative imaging.
Probe-based confocal laser endomicroscopy (pCLE) is a noninvasive technique that enables the direct visualization of tissue at a microscopic level in real time. One of the main challenges in using pCLE is maintaining the probe within a working range of micrometer scale. As a result, the need arises for automatically regressing the probe–tissue distance to enable precise robotic tissue scanning.
Methods
In this paper, we propose the spatial frequency bidirectional structured state space model (SF-BiS4D) for pCLE probe–tissue distance regression. This model advances traditional state space models by processing image sequences bidirectionally and analyzing data in both the frequency and spatial domains. Additionally, we introduce a guided trajectory planning strategy that generates pseudo-distance labels, facilitating the training of sequential models to generate smooth and stable robotic scanning trajectories. To improve inference speed, we also implement a hierarchical guided fine-tuning (GF) approach that efficiently reduces the size of the BiS4D model while maintaining performance.
Results
The performance of our proposed model has been evaluated both qualitatively and quantitatively using the pCLE regression dataset (PRD). In comparison with existing state-of-the-art (SOTA) methods, our approach demonstrated superior performance in terms of accuracy and stability.
Conclusion
Our proposed deep learning-based framework effectively improves distance regression for microscopic visual servoing and demonstrates its potential for integration into surgical procedures requiring precise real-time intraoperative imaging.
Date Issued
2025-06-01
Date Acceptance
2025-03-11
Citation
International Journal of Computer Assisted Radiology and Surgery, 2025, 20 (6), pp.1167-1174
ISSN
1861-6410
Publisher
Springer
Start Page
1167
End Page
1174
Journal / Book Title
International Journal of Computer Assisted Radiology and Surgery
Volume
20
Issue
6
Copyright Statement
© The Author(s) 2025 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
License URL
Identifier
10.1007/s11548-025-03353-w
Subjects
Distance regression
State space model
Fine-tuning
Robotic tissue scanning
Endomicroscopy
Publication Status
Published
Date Publish Online
2025-04-12