Repository logo
  • Log In
    Log in via Symplectic to deposit your publication(s).
Repository logo
  • Communities & Collections
  • Research Outputs
  • Statistics
  • Log In
    Log in via Symplectic to deposit your publication(s).
  1. Home
  2. Faculty of Engineering
  3. Faculty of Engineering
  4. Prestressed cold-formed steel beams: concept and mechanical behaviour
 
  • Details
Prestressed cold-formed steel beams: concept and mechanical behaviour
File(s)
Hadjipantelis et al. (2018) - Prestressed cold-formed steel beams.pdf (3.99 MB)
Accepted version
Author(s)
Hadjipantelis, N
Gardner, L
Wadee, MA
Type
Journal Article
Abstract
An innovative concept, whereby the load-carrying capacity and serviceability performance of cold-formed steel beams are enhanced by utilising prestressing techniques, is presented. The prestressing force is applied by means of a high-strength steel cable, which is housed at a location eccentric to the strong geometric axis within the bottom hollow flange of the cold-formed steel beam, inducing initial stresses in the beam that are opposite in sign to those introduced during the subsequent loading stage. As a consequence, the development of local instabilities during loading is delayed and thus the capacity of the beam is enhanced. Furthermore, the pre-camber induced during prestressing, as well as the contribution of the cable to the bending stiffness of the system, decrease the overall vertical deflections of the beam. The conceptual development of prestressed cold-formed steel beams and a study investigating the potential benefits are presented. The mechanical behaviour of the proposed beams in both the prestressing and imposed loading stages is described in terms of analytical expressions, while failure criteria for the design of the cold-formed steel beam and the cable are also developed by employing interaction equations in conjunction with the Direct Strength Method. Geometrically and materially nonlinear finite element analysis with imperfections is employed to simulate the behaviour of the proposed beams. Sample numerical results are presented and compared with the developed analytical expressions and failure criteria, demonstrating the substantial enhancement in moment capacity and serviceability performance offered by these beams.
Date Issued
2018-10-01
Date Acceptance
2018-06-06
Citation
Engineering Structures, 2018, 172 (1), pp.1057-1072
URI
http://hdl.handle.net/10044/1/61070
URL
https://www.sciencedirect.com/science/article/abs/pii/S0141029618304309?via%3Dihub
DOI
https://www.dx.doi.org/10.1016/j.engstruct.2018.06.027
ISSN
0141-0296
Publisher
Elsevier
Start Page
1057
End Page
1072
Journal / Book Title
Engineering Structures
Volume
172
Issue
1
Copyright Statement
© 2018 Elsevier Ltd. All rights reserved. This manuscript is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International http://creativecommons.org/licenses/by-nc-nd/4.0/
Subjects
0905 Civil Engineering
Civil Engineering
Publication Status
Published
Date Publish Online
2018-07-10
About
Spiral Depositing with Spiral Publishing with Spiral Symplectic
Contact us
Open access team Report an issue
Other Services
Scholarly Communications Library Services
logo

Imperial College London

South Kensington Campus

London SW7 2AZ, UK

tel: +44 (0)20 7589 5111

Accessibility Modern slavery statement Cookie Policy

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback