Repository logo
  • Log In
    Log in via Symplectic to deposit your publication(s).
Repository logo
  • Communities & Collections
  • Research Outputs
  • Statistics
  • Log In
    Log in via Symplectic to deposit your publication(s).
  1. Home
  2. Faculty of Engineering
  3. Dyson School of Design Engineering
  4. Oblique impact responses of Hybrid III and a new headform with more biofidelic coefficient of friction and moments of inertia
 
  • Details
Oblique impact responses of Hybrid III and a new headform with more biofidelic coefficient of friction and moments of inertia
File(s)
fbioe-10-860435.pdf (3.31 MB)
Published version
OA Location
https://www.frontiersin.org/articles/10.3389/fbioe.2022.860435/full
Author(s)
Yu, Xiancheng
Halldin, Peter
Ghajari, Mazdak
Type
Journal Article
Abstract
New oblique impact methods for evaluating head injury mitigation effects of helmets are emerging, which mandate measuring both translational and rotational kinematics of the headform. These methods need headforms with biofidelic mass, moments of inertia (MoIs) and coefficient of friction (CoF). To fulfil this need, the working group 11 of the European standardization head protection committee (CEN/TC158) has been working on the development of a new headform with realistic MoIs and CoF, based on recent biomechanics research on the human head. In this study, we used a version of this headform (Cellbond) to test a motorcycle helmet under oblique impacts at 8m/s at five different locations. We also used the Hybrid III headform, which is commonly used in helmet oblique impacts. We tested whether there is a difference between the predictions of the headforms in terms of injury metrics based on head kinematics, including peak translational and rotational acceleration, peak rotational velocity and BrIC (Brain Injury Criterion). We also used Imperial College finite element model of human head to predict strain and strain rate across the brain and tested whether there is a difference between the headforms in terms of predicted strain and strain rate. We found that the Cellbond headform produced similar or higher peak translational accelerations depending on the impact location (-3.2% in front-side impact to 24.3% in rear impact). The Cellbond headform however produced significantly lower peak rotational acceleration (-41.8% in rear impact to -62.7% in side impact), peak rotational velocity (-29.5% in side impact to -47.6% in rear impact) and BrIC (-29% in rear-side impact to -45.3% in rear impact). The 90th percentile value of the maximum brain strain and strain rate were also significantly lower using this headform. Our results suggest that MoIs and CoF have significant effects on headform rotational kinematics, and consequently brain deformation, during helmeted oblique impacts. Future helmet standards and rating methods should use headforms with realistic MoIs and CoF (e.g., the Cellbond headform) to ensure more accurate representation of the head in lab impact tests.
Date Issued
2022-09-08
Date Acceptance
2022-08-16
Citation
Frontiers in Bioengineering and Biotechnology, 2022, 10, pp.1-14
URI
http://hdl.handle.net/10044/1/99083
URL
https://www.frontiersin.org/articles/10.3389/fbioe.2022.860435/full
DOI
https://www.dx.doi.org/10.3389/fbioe.2022.860435
ISSN
2296-4185
Publisher
Frontiers Media
Start Page
1
End Page
14
Journal / Book Title
Frontiers in Bioengineering and Biotechnology
Volume
10
Copyright Statement
© 2022 Yu, Halldin and Ghajari. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
License URL
http://creativecommons.org/licenses/by/4.0/
Sponsor
Innovate UK
Identifier
https://www.frontiersin.org/articles/10.3389/fbioe.2022.860435/full
Grant Number
57460
Subjects
0699 Other Biological Sciences
0903 Biomedical Engineering
1004 Medical Biotechnology
Publication Status
Published
Article Number
860435
Date Publish Online
2022-09-08
About
Spiral Depositing with Spiral Publishing with Spiral Symplectic
Contact us
Open access team Report an issue
Other Services
Scholarly Communications Library Services
logo

Imperial College London

South Kensington Campus

London SW7 2AZ, UK

tel: +44 (0)20 7589 5111

Accessibility Modern slavery statement Cookie Policy

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback