Tuning the periodic V-peeling behavior of elastic tapes applied to thin compliant substrates
File(s)1911.08810.pdf (800.95 KB)
Accepted version
OA Location
Author(s)
Menga, Nicola
Dini, Daniele
Carbone, Guiseppe
Type
Journal Article
Abstract
In this paper, we investigate the periodic peeling behavior of opposing symmetric peeling fronts involving an elastic tape peeled off from a deformable substrate of finite thickness, backed onto a rigid foundation.
We treat the problem by means of an energetic formulation, and we found that, depending on the values of the initial detached length l, substrate thickness h, and peeling periodicity λ, the translational invariance of the peeling process is lost and restored, as the elastic interaction between the peeling fronts is limited by the substrate thickness. Indeed, given h and λ, a critical value of the detached length can be found, which is able to prevent unstable peeling of the tape under a fixed applied load, thus resulting in enhanced adhesion strength, with respect to the classical Kendall’s solution for peeling from a rigid substrate. On the other hand, given the geometrical system configuration (i.e. the detached length l) the load necessary to trigger the peeling can be minimized by conveniently tuning the ratio h/λ. This feature might be of interest for the development of innovative designs for future biomedical devices, such as Transdermal Drug Delivery Systems or wound dressing, requiring low peel adhesion for safe successive removals.
We treat the problem by means of an energetic formulation, and we found that, depending on the values of the initial detached length l, substrate thickness h, and peeling periodicity λ, the translational invariance of the peeling process is lost and restored, as the elastic interaction between the peeling fronts is limited by the substrate thickness. Indeed, given h and λ, a critical value of the detached length can be found, which is able to prevent unstable peeling of the tape under a fixed applied load, thus resulting in enhanced adhesion strength, with respect to the classical Kendall’s solution for peeling from a rigid substrate. On the other hand, given the geometrical system configuration (i.e. the detached length l) the load necessary to trigger the peeling can be minimized by conveniently tuning the ratio h/λ. This feature might be of interest for the development of innovative designs for future biomedical devices, such as Transdermal Drug Delivery Systems or wound dressing, requiring low peel adhesion for safe successive removals.
Date Issued
2020-03-15
Date Acceptance
2019-11-19
Citation
International Journal of Mechanical Sciences, 2020, 170
ISSN
0020-7403
Publisher
Elsevier
Journal / Book Title
International Journal of Mechanical Sciences
Volume
170
Copyright Statement
© 2019 Elsevier Ltd. All rights reserved. This manuscript is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International Licence http://creativecommons.org/licenses/by-nc-nd/4.0/
Sponsor
Engineering & Physical Science Research Council (EPSRC)
Commission of the European Communities
Identifier
https://www.sciencedirect.com/science/article/pii/S0020740319323033?via%3Dihub
Grant Number
EP/N025954/1
796954
Subjects
Mechanical Engineering & Transports
0910 Manufacturing Engineering
0905 Civil Engineering
0913 Mechanical Engineering
Publication Status
Published online
Article Number
105331
Date Publish Online
2019-11-22