Repository logo
  • Log In
    Log in via Symplectic to deposit your publication(s).
Repository logo
  • Communities & Collections
  • Research Outputs
  • Statistics
  • Log In
    Log in via Symplectic to deposit your publication(s).
  1. Home
  2. Faculty of Medicine
  3. Faculty of Medicine
  4. Motion-corrected multiparametric renal arterial spin labelling at 3T: Reproducibility and effect of vasodilator challenge
 
  • Details
Motion-corrected multiparametric renal arterial spin labelling at 3T: Reproducibility and effect of vasodilator challenge
File(s)
Shirvani2019_Article_Motion-correctedMultiparametri.pdf (982.91 KB)
Published version
Author(s)
Shirvani, Saba
Tokarczuk, Pawel
Statton, Ben
Quinlan, Marina
Berry, Alaine
more
Type
Journal Article
Abstract
Objectives

We investigated the feasibility and reproducibility of free-breathing motion-corrected multiple inversion time (multi-TI) pulsed renal arterial spin labelling (PASL), with general kinetic model parametric mapping, to simultaneously quantify renal perfusion (RBF), bolus arrival time (BAT) and tissue T1.
Methods

In a study approved by the Health Research Authority, 12 healthy volunteers (mean age, 27.6 ± 18.5 years; 5 male) gave informed consent for renal imaging at 3 T using multi-TI ASL and conventional single-TI ASL. Glyceryl trinitrate (GTN) was used as a vasodilator challenge in six subjects. Flow-sensitive alternating inversion recovery (FAIR) preparation was used with background suppression and 3D-GRASE (gradient and spin echo) read-out, and images were motion-corrected. Parametric maps of RBF, BAT and T1 were derived for both kidneys. Agreement was assessed using Pearson correlation and Bland-Altman plots.
Results

Inter-study correlation of whole-kidney RBF was good for both single-TI (r2 = 0.90), and multi-TI ASL (r2 = 0.92). Single-TI ASL gave a higher estimate of whole-kidney RBF compared to multi-TI ASL (mean bias, 29.3 ml/min/100 g; p <0.001). Using multi-TI ASL, the median T1 of renal cortex was shorter than that of medulla (799.6 ms vs 807.1 ms, p = 0.01), and mean whole-kidney BAT was 269.7 ± 56.5 ms. GTN had an effect on systolic blood pressure (p < 0.05) but the change in RBF was not significant.
Conclusions

Free-breathing multi-TI renal ASL is feasible and reproducible at 3 T, providing simultaneous measurement of renal perfusion, haemodynamic parameters and tissue characteristics at baseline and during pharmacological challenge.
Date Issued
2019-01-31
Date Acceptance
2018-06-22
Citation
European Radiology, 2019, 29 (1), pp.232-240
URI
http://hdl.handle.net/10044/1/61596
URL
https://link.springer.com/article/10.1007%2Fs00330-018-5628-3
DOI
https://www.dx.doi.org/10.1007/s00330-018-5628-3
ISSN
0938-7994
Publisher
Springer Verlag
Start Page
232
End Page
240
Journal / Book Title
European Radiology
Volume
29
Issue
1
Copyright Statement
© The Author(s) 2018. This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
Sponsor
Imperial College Healthcare NHS Trust- BRC Funding
Medical Research Council (MRC)
Identifier
https://link.springer.com/article/10.1007%2Fs00330-018-5628-3
Grant Number
RDC04
PO#4050724483
Subjects
Science & Technology
Life Sciences & Biomedicine
Radiology, Nuclear Medicine & Medical Imaging
Blood flow velocity
Computer-assisted image processing
Magnetic resonance imaging
Renal circulation
Vasodilator agents
BLOOD-FLOW
CORTICOMEDULLARY DIFFERENTIATION
NONINVASIVE MEASUREMENT
PERFUSION
ASL
QUANTIFICATION
MRI
AUTOREGULATION
HEALTH
TIME
Blood flow velocity
Computer-assisted image processing
Magnetic resonance imaging
Renal circulation
Vasodilator agents
Adult
Female
Healthy Volunteers
Humans
Kidney
Magnetic Resonance Imaging
Male
Prospective Studies
Renal Artery
Reproducibility of Results
Spin Labels
Vasodilation
Vasodilator Agents
Kidney
Renal Artery
Humans
Spin Labels
Vasodilator Agents
Magnetic Resonance Imaging
Prospective Studies
Reproducibility of Results
Vasodilation
Adult
Female
Male
Healthy Volunteers
1103 Clinical Sciences
Nuclear Medicine & Medical Imaging
Publication Status
Published
Date Publish Online
2018-07-10
About
Spiral Depositing with Spiral Publishing with Spiral Symplectic
Contact us
Open access team Report an issue
Other Services
Scholarly Communications Library Services
logo

Imperial College London

South Kensington Campus

London SW7 2AZ, UK

tel: +44 (0)20 7589 5111

Accessibility Modern slavery statement Cookie Policy

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback