  4. A systematic review and meta-analysis of the diagnostic accuracy of biparametric prostate MRI for prostate cancer in men at risk
 
  • Details
A systematic review and meta-analysis of the diagnostic accuracy of biparametric prostate MRI for prostate cancer in men at risk
File(s)
PCAN manuscript clean revision.docx (81.73 KB)
Accepted version
Author(s)
Bass, Edward
Pantovic, Ana
Connor, Martin
Gabe, Rhian
Padhani, Anwar
more
Type
Journal Article
Abstract
Introduction

Multiparametric magnetic resonance imaging (mpMRI), the use of three multiple imaging sequences, typically T2-weighted, diffusion weighted (DWI) and dynamic contrast enhanced (DCE) images, has a high sensitivity and specificity for detecting significant cancer. Current guidance now recommends its use prior to biopsy. However, the impact of DCE is currently under debate regarding test accuracy. Biparametric MRI (bpMRI), using only T2 and DWI has been proposed as a viable alternative. We conducted a contemporary systematic review and meta-analysis to further examine the diagnostic performance of bpMRI in the diagnosis of any and clinically significant prostate cancer.
Methods

A systematic review of the literature from 01/01/2017 to 06/07/2019 was performed by two independent reviewers using predefined search criteria. The index test was biparametric MRI and the reference standard whole-mount prostatectomy or prostate biopsy. Quality of included studies was assessed by the QUADAS-2 tool. Statistical analysis included pooled diagnostic performance (sensitivity; specificity; AUC), meta-regression of possible covariates and head-to-head comparisons of bpMRI and mpMRI where both were performed in the same study.
Results

Forty-four articles were included in the analysis. The pooled sensitivity for any cancer detection was 0.84 (95% CI, 0.80–0.88), specificity 0.75 (95% CI, 0.68–0.81) for bpMRI. The summary ROC curve yielded a high AUC value (AUC = 0.86). The pooled sensitivity for clinically significant prostate cancer was 0.87 (95% CI, 0.78–0.93), specificity 0.72 (95% CI, 0.56–0.84) and the AUC value was 0.87. Meta-regression analysis revealed no difference in the pooled diagnostic estimates between bpMRI and mpMRI.
Conclusions

This meta-analysis on contemporary studies shows that bpMRI offers comparable test accuracies to mpMRI in detecting prostate cancer. These data are broadly supportive of the bpMRI approach but heterogeneity does not allow definitive recommendations to be made. There is a need for prospective multicentre studies of bpMRI in biopsy naïve men.
Date Issued
2021-09-01
Date Acceptance
2020-10-19
Citation
Prostate Cancer and Prostatic Diseases, 2021, 24, pp.596-611
URI
http://hdl.handle.net/10044/1/84888
DOI
https://www.dx.doi.org/10.1038/s41391-020-00298-w
ISSN
1365-7852
Publisher
Springer Nature [academic journals on nature.com]
Start Page
596
End Page
611
Journal / Book Title
Prostate Cancer and Prostatic Diseases
Volume
24
Copyright Statement
© 2020, Crown. Published by Springer Nature.
Sponsor
Cancer Research UK
Imperial College Healthcare NHS Trust- BRC Funding
Wellcome Trust
Wellcome Trust
Grant Number
25147
RDC04
204998/Z/16/Z
204998/Z/16/Z
Subjects
Science & Technology
Life Sciences & Biomedicine
Oncology
Urology & Nephrology
DIFFUSION-WEIGHTED MRI
PHASED-ARRAY COIL
MULTIPARAMETRIC MRI
ENDORECTAL COIL
TUMOR-DETECTION
3 T
COEFFICIENT MAP
VERSION 2
ANTIGEN
BIOPSY
Urology & Nephrology
1112 Oncology and Carcinogenesis
Publication Status
Published
Date Publish Online
2020-11-20
About
Spiral Depositing with Spiral Publishing with Spiral Symplectic
Contact us
Open access team Report an issue
Other Services
Scholarly Communications Library Services
logo

Imperial College London

South Kensington Campus

London SW7 2AZ, UK

tel: +44 (0)20 7589 5111

Accessibility Modern slavery statement Cookie Policy

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback