Four-dimensional analysis of aortic root motion in normal population using retrospective multiphase computed tomography
File(s) qyae007.pdf (786.19 KB)
Published version
Author(s)
Type
Journal Article
Abstract
Aims:
Aortic root motion is suspected to contribute to proximal aortic dissection. While motion of the aorta in four dimensions can be traced with real-time imaging, displacement and rotation in quantitative terms remain unknown. The hypothesis was to show feasibility of quantification of three-dimensional aortic root motion from dynamic CT imaging.
Methods and results:
Dynamic CT images of 40 patients for coronary assessment were acquired using a dynamic protocol. Scans were ECG-triggered and segmented in 10 time-stepped phases (0–90%) per cardiac cycle. With identification of the sinotubular junction (STJ), a patient-specific co-ordinate system was created with the z-axis (out-of-plane) parallel to longitudinal direction. The left and right coronary ostia were traced at each time-step to quantify downward motion in reference to the STJ plane, motion within the STJ plane (in-plane), and the degree of rotation. Enrolled individuals had an age of 65 ± 12, and 14 were male (35%). The out-of-plane motion was recorded with the largest displacement of 10.26 ± 2.20 and 8.67 ± 1.69 mm referenced by left and right coronary ostia, respectively. The mean downward movement of aortic root was 9.13 ± 1.86 mm. The largest in-plane motion was recorded at 9.17 ± 2.33 mm and 6.51 ± 1.75 mm referenced by left and right coronary ostia, respectively. The largest STJ in-plane motion was 7.37 ± 1.96 mm, and rotation of the aortic root was 11.8 ± 4.60°.
Conclusion:
In vivo spatial and temporal displacement of the aortic root can be identified and quantified from multiphase ECG-gated contrast-enhanced CT images. Knowledge of normal 4D motion of the aortic root may help understand its biomechanical impact in patients with aortopathy and pre- and post-surgical or transcatheter aortic valve replacement.
Aortic root motion is suspected to contribute to proximal aortic dissection. While motion of the aorta in four dimensions can be traced with real-time imaging, displacement and rotation in quantitative terms remain unknown. The hypothesis was to show feasibility of quantification of three-dimensional aortic root motion from dynamic CT imaging.
Methods and results:
Dynamic CT images of 40 patients for coronary assessment were acquired using a dynamic protocol. Scans were ECG-triggered and segmented in 10 time-stepped phases (0–90%) per cardiac cycle. With identification of the sinotubular junction (STJ), a patient-specific co-ordinate system was created with the z-axis (out-of-plane) parallel to longitudinal direction. The left and right coronary ostia were traced at each time-step to quantify downward motion in reference to the STJ plane, motion within the STJ plane (in-plane), and the degree of rotation. Enrolled individuals had an age of 65 ± 12, and 14 were male (35%). The out-of-plane motion was recorded with the largest displacement of 10.26 ± 2.20 and 8.67 ± 1.69 mm referenced by left and right coronary ostia, respectively. The mean downward movement of aortic root was 9.13 ± 1.86 mm. The largest in-plane motion was recorded at 9.17 ± 2.33 mm and 6.51 ± 1.75 mm referenced by left and right coronary ostia, respectively. The largest STJ in-plane motion was 7.37 ± 1.96 mm, and rotation of the aortic root was 11.8 ± 4.60°.
Conclusion:
In vivo spatial and temporal displacement of the aortic root can be identified and quantified from multiphase ECG-gated contrast-enhanced CT images. Knowledge of normal 4D motion of the aortic root may help understand its biomechanical impact in patients with aortopathy and pre- and post-surgical or transcatheter aortic valve replacement.
Date Issued
2024-02-05
Date Acceptance
2024-01-30
Citation
European Heart Journal - Imaging Method and Practice, 2024, 2 (1)
ISSN
2755-9637
Publisher
Oxford University Press
Journal / Book Title
European Heart Journal - Imaging Method and Practice
Volume
2
Issue
1
Copyright Statement
© The Author(s) 2024. Published by Oxford University Press on behalf of the European Society of Cardiology.
This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial License (https://creativecommons.org/licenses/by-nc/4.0/), which permits
non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial License (https://creativecommons.org/licenses/by-nc/4.0/), which permits
non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
License URL
Publication Status
Published
Date Publish Online
2024-02-05
