Purpose
[18F]-fluorothymidine ([18F]-FLT) is a PET-tracer enabling in-vivo visualization and quantification of tumor cell proliferation. For qualitative and quantitative analysis, adequate knowledge of normal tissue uptake is indispensable. This study aimed to quantitatively investigate baseline tracer uptake of blood pool, lung, liver and bone marrow and their precision, and to assess the longitudinal effect of systemic treatment on biodistribution.
Methods
18F–FLT-PET(/CT) scans (dynamic or static) of 90 treatment-naïve oncological patients were retrospectively evaluated. Twenty-three patients received double baseline scans, and another 39 patients were also scanned early and late during systemic treatment with a tyrosine kinase inhibitor. Reproducible volume of interest were placed in blood pool, lung, liver, and bone marrow. For semi-quantitative analysis, SUVmean, SUVmax, and SUVpeak with several normalizations were derived.
Results
SUVs of basal lung, liver, and bone marrow were not significantly different between averaged dynamic and static images, in contrast with blood pool and apical lung. Highest repeatability was seen for liver and bone marrow, with repeatability coefficients of 18.6% and 20.4% when using SUVpeak. Systemic treatment with TKIs both increased and decreased normal tissue tracer uptake at early and late time points during treatment.
Conclusion
Simultaneous evaluation of liver and bone marrow uptake in longitudinal response studies may be used to assess image quality, where changes in uptake outside repeatability limits should trigger investigators to perform additional quality control on individual PET images.
Advances in knowledge
For [18F]-FLT PET images, liver and bone marrow have low intra-patient variability when quantified with SUVpeak, but may be affected by systemic treatment.
Implications for patient care
In [18F]-FLT-PET response monitoring trials, liver and bone marrow uptake may be used for quality control of [18F]-FLT PET images.
[18F]-fluorothymidine ([18F]-FLT) is a PET-tracer enabling in-vivo visualization and quantification of tumor cell proliferation. For qualitative and quantitative analysis, adequate knowledge of normal tissue uptake is indispensable. This study aimed to quantitatively investigate baseline tracer uptake of blood pool, lung, liver and bone marrow and their precision, and to assess the longitudinal effect of systemic treatment on biodistribution.
Methods
18F–FLT-PET(/CT) scans (dynamic or static) of 90 treatment-naïve oncological patients were retrospectively evaluated. Twenty-three patients received double baseline scans, and another 39 patients were also scanned early and late during systemic treatment with a tyrosine kinase inhibitor. Reproducible volume of interest were placed in blood pool, lung, liver, and bone marrow. For semi-quantitative analysis, SUVmean, SUVmax, and SUVpeak with several normalizations were derived.
Results
SUVs of basal lung, liver, and bone marrow were not significantly different between averaged dynamic and static images, in contrast with blood pool and apical lung. Highest repeatability was seen for liver and bone marrow, with repeatability coefficients of 18.6% and 20.4% when using SUVpeak. Systemic treatment with TKIs both increased and decreased normal tissue tracer uptake at early and late time points during treatment.
Conclusion
Simultaneous evaluation of liver and bone marrow uptake in longitudinal response studies may be used to assess image quality, where changes in uptake outside repeatability limits should trigger investigators to perform additional quality control on individual PET images.
Advances in knowledge
For [18F]-FLT PET images, liver and bone marrow have low intra-patient variability when quantified with SUVpeak, but may be affected by systemic treatment.
Implications for patient care
In [18F]-FLT-PET response monitoring trials, liver and bone marrow uptake may be used for quality control of [18F]-FLT PET images.
Date Issued
2017-05-10
Date Acceptance
2017-05-04
Citation
Nuclear Medicine and Biology, 2017, 51, pp.18-24
ISSN
0969-8051
Publisher
Elsevier
Start Page
18
End Page
24
Journal / Book Title
Nuclear Medicine and Biology
Volume
51
Copyright Statement
© 2017 The Authors. Published by Elsevier Inc. This is an open access article under the CC BY license
(http://creativecommons.org/licenses/by/4.0/).
(http://creativecommons.org/licenses/by/4.0/).
Sponsor
Cancer Research UK
Identifier
http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=WOS:000404832300003&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=1ba7043ffcc86c417c072aa74d649202
Grant Number
C2536/A16584
Subjects
Science & Technology
Life Sciences & Biomedicine
Radiology, Nuclear Medicine & Medical Imaging
F-18-FLT
PET
Normal tissue uptake values
Quality control
POSITRON-EMISSION-TOMOGRAPHY
CANCER-PATIENTS
LUNG-CANCER
ROI DEFINITION
F-18-FDG PET
REPRODUCIBILITY
PROLIFERATION
Publication Status
Published