Experimental analysis of surface finish in normal conducting cavities
File(s) 10.1016:j.nima.2017.06.037.pdf (1010.77 KB)
Accepted version
Author(s)
Zarrebini-Esfahani, A
Aslaninejad, M
Ristic, M
Long, K
Type
Journal Article
Abstract
A normal conducting 805 MHz test cavity with an in built button shaped sample is used to conduct a series of surface treatment experiments. The button enhances the local fields and influences the likelihood of an RF breakdown event. Because of their smaller sizes, compared to the whole cavity surface, they allow practical investigations of the effects of cavity surface preparation in relation to RF breakdown. Manufacturing techniques and steps for preparing the buttons to improve the surface quality are described in detail. It was observed that even after the final stage of the surface treatment, defects on the surface of the cavities still could be found.
Date Issued
2017-07-18
Date Acceptance
2017-06-23
Citation
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2017, 869, pp.76-83
ISSN
0168-9002
Publisher
Elsevier
Start Page
76
End Page
83
Journal / Book Title
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Volume
869
Copyright Statement
© 2017, Elsevier. Licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International http://creativecommons.org/licenses/by-nc-nd/4.0/
Sponsor
Science and Technology Facilities Council (STFC)
Grant Number
ST/H001735/1 MICE/UKNF
Subjects
Science & Technology
Technology
Physical Sciences
Instruments & Instrumentation
Nuclear Science & Technology
Physics, Nuclear
Physics, Particles & Fields
Physics
RF breakdown
Surface finish
Cavity
Electropolish
Electroplating
Publication Status
Published
Date Publish Online
2017-07-18