Abstract
Hand musculoskeletal models provide a valuable insight into the loads withstood by the upper limb; however, their development remains challenging because there are few datasets describing both the musculoskeletal geometry and muscle morphology from the elbow to the finger tips. Clinical imaging, optical motion capture and microscopy were used to create a dataset from a single specimen. Subsequently, a musculoskeletal model of the wrist was developed based on these data to estimate muscle tensions and to demonstrate the potential of the provided parameters. Tendon excursions and moment arms predicted by this model were in agreement with previously reported experimental data. When simulating a flexion-extension motion, muscle forces reached 90 N among extensors and a co-contraction of flexors, amounting to 62.6 N, was estimated by the model. Two alternative musculoskeletal models were also created based on anatomical data available in the literature to illustrate the effect of combining incomplete datasets. Compared to the initial model, the intensities and load sharing of the muscles estimated by the two alternative models differed by up to 180% for a single muscle. This confirms the importance of using a single source of anatomical data when developing such models.
Date Issued
2018-01-01
Date Acceptance
2017-09-20
Citation
Annals of Biomedical Engineering, 2018, 46 (1), pp.71-85
ISSN
0090-6964
Publisher
Springer Verlag
Start Page
71
End Page
85
Journal / Book Title
Annals of Biomedical Engineering
Volume
46
Issue
1
Copyright Statement
© The Author(s) 2017. This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
License URL
Sponsor
Arthritis Research UK
Arthritis Research UK
The Royal Society
Grant Number
20556
20680
RG130400
Subjects
clinical imaging
motion capture
digitization
instantaneous helical axes
sarcomere length
moments arms
tendon excursion
muscle force
Publication Status
Published
Date Publish Online