Faster, more reproducible DESI-MS for biological tissue imaging
File(s)10.1007-s13361-017-1714-z.pdf (3.51 MB)
Published version
Author(s)
Type
Journal Article
Abstract
A new, more robust sprayer for desorption electrospray ionization (DESI) mass spectrometry imaging is presented. The main source of variability in DESI is thought to be the uncontrolled variability of various geometric parameters of the sprayer, primarily the position of the solvent capillary, or more specifically, its positioning within the gas capillary or nozzle. If the solvent capillary is off-center, the sprayer becomes asymmetrical, making the geometry difficult to control and compromising reproducibility. If the stiffness, tip quality, and positioning of the capillary are improved, sprayer reproducibility can be improved by an order of magnitude. The quality of the improved sprayer and its potential for high spatial resolution imaging are demonstrated on human colorectal tissue samples by acquisition of images at pixel sizes of 100, 50, and 20 μm, which corresponds to a lateral resolution of 40-60 μm, similar to the best values published in the literature. The high sensitivity of the sprayer also allows combination with a fast scanning quadrupole time-of-flight mass spectrometer. This provides up to 30 times faster DESI acquisition, reducing the overall acquisition time for a 10 mm × 10 mm rat brain sample to approximately 1 h. Although some spectral information is lost with increasing analysis speed, the resulting data can still be used to classify tissue types on the basis of a previously constructed model. This is particularly interesting for clinical applications, where fast, reliable diagnosis is required. Graphical Abstract ᅟ.
Date Issued
2017-06-15
Date Acceptance
2017-04-23
Citation
Journal of The American Society for Mass Spectrometry, 2017, 28 (10), pp.2090-2098
ISSN
1044-0305
Publisher
Springer Verlag
Start Page
2090
End Page
2098
Journal / Book Title
Journal of The American Society for Mass Spectrometry
Volume
28
Issue
10
Copyright Statement
© The Author(s) 2017
This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
License URL
Sponsor
Commission of the European Communities
Identifier
PII: 10.1007/s13361-017-1714-z
Grant Number
634402
Subjects
DESI-MS
Desorption electrospray ionization
Fast DESI
Mass spectrometry imaging
Publication Status
Published