Standard care vs. TRIVEntricular pacing in Heart Failure (STRIVE HF): a prospective multicentre randomized controlled trial of triventricular pacing vs. conventional biventricular pacing in patients with heart failure and intermediate QRS left bundle branch block
Author(s)
Type
Journal Article
Abstract
Aims
To determine whether triventricular (TriV) pacing is feasible and improves CRT response compared to conventional biventricular (BiV) pacing in patients with left bundle branch block (LBBB) and intermediate QRS prolongation (120–150 ms).
Methods and results
Between October 2015 and November 2019, 99 patients were recruited from 11 UK centres. Ninety-five patients were randomized 1:1 to receive TriV or BiV pacing systems. The primary endpoint was feasibility of TriV pacing. Secondary endpoints assessed symptomatic and remodelling response to CRT. Baseline characteristics were balanced between groups. In the TriV group, 43/46 (93.5%) patients underwent successful implantation vs. 47/49 (95.9%) in the BiV group. Feasibility of maintaining CRT at 6 months was similar in the TriV vs. BiV group (90.0% vs. 97.7%, P = 0.191). All-cause mortality was similar between TriV vs. BiV groups (4.3% vs. 8.2%, P = 0.678). There were no significant differences in echocardiographic LV volumes or clinical composite scores from baseline to 6-month follow-up between groups.
Conclusion
Implantation of two LV leads to deliver and maintain TriV pacing at 6 months is feasible without significant complications in the majority of patients. There was no evidence that TriV pacing improves CRT response or provides additional clinical benefit to patients with LBBB and intermediate QRS prolongation and cannot be recommended in this patient group.
Clinical trial registration number
Clinicaltrials.gov: NCT02529410.
To determine whether triventricular (TriV) pacing is feasible and improves CRT response compared to conventional biventricular (BiV) pacing in patients with left bundle branch block (LBBB) and intermediate QRS prolongation (120–150 ms).
Methods and results
Between October 2015 and November 2019, 99 patients were recruited from 11 UK centres. Ninety-five patients were randomized 1:1 to receive TriV or BiV pacing systems. The primary endpoint was feasibility of TriV pacing. Secondary endpoints assessed symptomatic and remodelling response to CRT. Baseline characteristics were balanced between groups. In the TriV group, 43/46 (93.5%) patients underwent successful implantation vs. 47/49 (95.9%) in the BiV group. Feasibility of maintaining CRT at 6 months was similar in the TriV vs. BiV group (90.0% vs. 97.7%, P = 0.191). All-cause mortality was similar between TriV vs. BiV groups (4.3% vs. 8.2%, P = 0.678). There were no significant differences in echocardiographic LV volumes or clinical composite scores from baseline to 6-month follow-up between groups.
Conclusion
Implantation of two LV leads to deliver and maintain TriV pacing at 6 months is feasible without significant complications in the majority of patients. There was no evidence that TriV pacing improves CRT response or provides additional clinical benefit to patients with LBBB and intermediate QRS prolongation and cannot be recommended in this patient group.
Clinical trial registration number
Clinicaltrials.gov: NCT02529410.
Date Issued
2021-11-22
Date Acceptance
2021-11-01
Citation
Europace, 2021, 24 (5), pp.796-806
ISSN
1099-5129
Publisher
Oxford University Press
Start Page
796
End Page
806
Journal / Book Title
Europace
Volume
24
Issue
5
Copyright Statement
© The Author(s) 2021. Published by Oxford University Press on behalf of the European Society of Cardiology
This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited.
This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited.
License URL
Identifier
https://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=WOS:000790151200001&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=a2bf6146997ec60c407a63945d4e92bb
Subjects
BENEFITS
Cardiac & Cardiovascular Systems
Cardiac resynchronization therapy
CARDIAC-RESYNCHRONIZATION THERAPY
Cardiovascular System & Cardiology
DURATION
GUIDELINES
IMPACT
Improving cardiac resynchronization therapy response
INSIGHTS
Life Sciences & Biomedicine
Multi-lead left ventricular pacing
Multi-site pacing
Science & Technology
SITE
Triventricular pacing
Publication Status
Published
Date Publish Online
2021-11-22