Improved quantitation and reproducibility in multi-PET/CT lung studies by combining CT information
Author(s)
Type
Journal Article
Abstract
BACKGROUND: Matched attenuation maps are vital for obtaining accurate and reproducible kinetic and static parameter estimates from PET data. With increased interest in PET/CT imaging of diffuse lung diseases for assessing disease progression and treatment effectiveness, understanding the extent of the effect of respiratory motion and establishing methods for correction are becoming more important. In a previous study, we have shown that using the wrong attenuation map leads to large errors due to density mismatches in the lung, especially in dynamic PET scans. Here, we extend this work to the case where the study is sub-divided into several scans, e.g. for patient comfort, each with its own CT (cine-CT and 'snap shot' CT). A method to combine multi-CT information into a combined-CT has then been developed, which averages the CT information from each study section to produce composite CT images with the lung density more representative of that in the PET data. This combined-CT was applied to nine patients with idiopathic pulmonary fibrosis, imaged with dynamic 18F-FDG PET/CT to determine the improvement in the precision of the parameter estimates. RESULTS: Using XCAT simulations, errors in the influx rate constant were found to be as high as 60% in multi-PET/CT studies. Analysis of patient data identified displacements between study sections in the time activity curves, which led to an average standard error in the estimates of the influx rate constant of 53% with conventional methods. This reduced to within 5% after use of combined-CTs for attenuation correction of the study sections. CONCLUSIONS: Use of combined-CTs to reconstruct the sections of a multi-PET/CT study, as opposed to using the individually acquired CTs at each study stage, produces more precise parameter estimates and may improve discrimination between diseased and normal lung.
Date Issued
2018-06-05
Date Acceptance
2018-04-09
Citation
EJNMMI Physics, 2018, 5 (1)
ISSN
2197-7364
Publisher
SpringerOpen
Journal / Book Title
EJNMMI Physics
Volume
5
Issue
1
Copyright Statement
© The Author(s). 2018.
This article is distributed under the terms of the Creative Commons Attribution 4.0
International License (
http://creativecommons.org/licenses/by/4.0/
), which permits unrestricted use, distribution, and
reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the
Creative Commons license, and indicate if changes were made.
This article is distributed under the terms of the Creative Commons Attribution 4.0
International License (
http://creativecommons.org/licenses/by/4.0/
), which permits unrestricted use, distribution, and
reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the
Creative Commons license, and indicate if changes were made.
Identifier
https://www.ncbi.nlm.nih.gov/pubmed/29869186
PII: 10.1186/s40658-018-0212-0
Subjects
Attenuation correction
Density
Dynamic PET
Lung
PET/CT
Quantitation
Respiration
Publication Status
Published
Coverage Spatial
Germany
Article Number
ARTN 14