Reliability and minimal detectable change of the ‘Imperial Spine’ marker set for the evaluation of spinal and lower limb kinematics in adults
File(s)s13104-020-05295-9.pdf (1.89 MB)
Published version
Author(s)
Deane, Janet A
Papi, Enrica
Phillips, Andrew
McGregor, Alison
Type
Journal Article
Abstract
Objectives
As a step towards the comprehensive evaluation of movement in patients with low back pain, the aim of this study is to design a marker set (three rigid segment spine, pelvic and lower limb model) and evaluate the reliability and minimal detectable change (MDC) of this marker set in healthy adults during gait and sit to stand (STS) tasks using three dimensional motion capture.
Results
The ‘Imperial Spine’ marker set was used to assess relative peak angles during gait and STS tasks using the minimum recommended sample size (n = 10) for reliability studies with minimum Intraclass Correlation Coefficient (ICC) of 0.70, optimum ICC 0.90 and 9 trials replicated per subject per task. Intra- and inter-tester reliability between an experienced and inexperienced user was examined. ICC, mean, standard error (SEM), Bland Altman 95% limits of agreement (LOA) and MDC were computed.
ICC values demonstrated excellent intra- and inter-tester reliability in both tasks, particularly in the sagittal plane (majority ICCs > 0.80). SEM measurements were lower in gait (0.8–5.5°) than STS tasks (1°-12.6°) as were MDC values. LOA demonstrated good agreement. The ‘Imperial Spine’ marker set is reliable for use in healthy adults during functional tasks. Future evaluation in patients is required.
As a step towards the comprehensive evaluation of movement in patients with low back pain, the aim of this study is to design a marker set (three rigid segment spine, pelvic and lower limb model) and evaluate the reliability and minimal detectable change (MDC) of this marker set in healthy adults during gait and sit to stand (STS) tasks using three dimensional motion capture.
Results
The ‘Imperial Spine’ marker set was used to assess relative peak angles during gait and STS tasks using the minimum recommended sample size (n = 10) for reliability studies with minimum Intraclass Correlation Coefficient (ICC) of 0.70, optimum ICC 0.90 and 9 trials replicated per subject per task. Intra- and inter-tester reliability between an experienced and inexperienced user was examined. ICC, mean, standard error (SEM), Bland Altman 95% limits of agreement (LOA) and MDC were computed.
ICC values demonstrated excellent intra- and inter-tester reliability in both tasks, particularly in the sagittal plane (majority ICCs > 0.80). SEM measurements were lower in gait (0.8–5.5°) than STS tasks (1°-12.6°) as were MDC values. LOA demonstrated good agreement. The ‘Imperial Spine’ marker set is reliable for use in healthy adults during functional tasks. Future evaluation in patients is required.
Date Issued
2020-10-22
Date Acceptance
2020-09-16
Citation
BMC Research Notes, 2020, 13
ISSN
1756-0500
Publisher
BioMed Central
Journal / Book Title
BMC Research Notes
Volume
13
Copyright Statement
© 2020 The Author(s). This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing,
adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and
the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material
in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material
is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the
permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativeco
mmons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/
zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and
the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material
in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material
is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the
permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativeco
mmons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/
zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
License URL
Sponsor
Arthritis Research UK
Versus Arthritis
Grant Number
20172
Subjects
Gait
Kinematics
Low back pain
Marker set
Minimal detectable change
Motion technology
Reliability
Sit to stand
Spine
Three dimensional motion capture
0601 Biochemistry and Cell Biology
1199 Other Medical and Health Sciences
Bioinformatics
Publication Status
Published
Article Number
495
Date Publish Online
2020-10-22