Towards a core outcome set for abdominal aortic aneurysm: systematic review of outcomes reported following intact and ruptured abdominal aortic aneurysm repair
File(s)AAACOSNovR1refsupclean.docx (163.23 KB) Supplementary data_15.09R1.docx (52.37 KB)
Accepted version
Supporting information
Author(s)
Machin, Matthew
Ulug, Pinar
Pandirajan, Kamashi
Bown, Matthew
Powell, Janet
Type
Journal Article
Abstract
Objective:
To encompass the needs of all stakeholders and allow effective data synthesis from trials, registries, and other studies; a core outcome set for infrarenal abdominal aortic aneurysm (AAA) repair is needed. In this first stage, the aim was to report the range, frequency, and time of pre-specified outcomes reported following AAA repair.
Data Sources:
Medline, Embase, and CENTRAL databases 2010 – 2019 were searched using ProQuest Dialog™.
Review Methods:
The systematic review was reported to Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines (PRISMA), PROSPERO registration CRD42019130119. Outcomes were coded using Core Outcome Measures in Effectiveness Trials (COMET) taxonomy and presented separately for intact and rupture repairs, endovascular aneurysm repair (EVAR) and open repair, and time from repair (acute < 90 days vs. ≥ 1 year) (COMET Initiative 1582).
Results:
For intact AAA and rupture repair, a total of 231 and 70 reports with 589 255 and 177 465 patients respectively were included: only 98 and 19 respectively provided ≥ 1 year outcomes. Most studies were retrospective, with 13 randomised trials of intact AAA repair and five randomised trials of ruptured AAA repair. For intact AAA, the most common pre-specified COMET taxonomy outcomes were mortality (181), vascular complications (137), and re-intervention (52). EVAR studies dominated the vascular outcomes in acute and later time periods: excluding 47 reports from device registries, reduced vascular outcomes to 83. For ruptured AAA, the three most common outcomes were mortality (64), vascular (11), and hospital stay (10). The range of outcomes reported was wide with functioning outcomes reported from most randomised trials but few retrospective studies.
Conclusion:
This review identifies the paucity of long term data and the disproportionate attention paid to vascular complications vs. patient functioning outcomes, this skew being accentuated by reporting from EVAR device registries. These data will inform focus groups, prior to a pan-European Delphi consensus, involving clinicians, patients, carers and providers, for developing core outcomes for repair of intact and ruptured AAA.
To encompass the needs of all stakeholders and allow effective data synthesis from trials, registries, and other studies; a core outcome set for infrarenal abdominal aortic aneurysm (AAA) repair is needed. In this first stage, the aim was to report the range, frequency, and time of pre-specified outcomes reported following AAA repair.
Data Sources:
Medline, Embase, and CENTRAL databases 2010 – 2019 were searched using ProQuest Dialog™.
Review Methods:
The systematic review was reported to Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines (PRISMA), PROSPERO registration CRD42019130119. Outcomes were coded using Core Outcome Measures in Effectiveness Trials (COMET) taxonomy and presented separately for intact and rupture repairs, endovascular aneurysm repair (EVAR) and open repair, and time from repair (acute < 90 days vs. ≥ 1 year) (COMET Initiative 1582).
Results:
For intact AAA and rupture repair, a total of 231 and 70 reports with 589 255 and 177 465 patients respectively were included: only 98 and 19 respectively provided ≥ 1 year outcomes. Most studies were retrospective, with 13 randomised trials of intact AAA repair and five randomised trials of ruptured AAA repair. For intact AAA, the most common pre-specified COMET taxonomy outcomes were mortality (181), vascular complications (137), and re-intervention (52). EVAR studies dominated the vascular outcomes in acute and later time periods: excluding 47 reports from device registries, reduced vascular outcomes to 83. For ruptured AAA, the three most common outcomes were mortality (64), vascular (11), and hospital stay (10). The range of outcomes reported was wide with functioning outcomes reported from most randomised trials but few retrospective studies.
Conclusion:
This review identifies the paucity of long term data and the disproportionate attention paid to vascular complications vs. patient functioning outcomes, this skew being accentuated by reporting from EVAR device registries. These data will inform focus groups, prior to a pan-European Delphi consensus, involving clinicians, patients, carers and providers, for developing core outcomes for repair of intact and ruptured AAA.
Date Issued
2021-06-01
Date Acceptance
2021-02-04
Citation
European Journal of Vascular and Endovascular Surgery, 2021, 61 (6), pp.909-918
ISSN
1078-5884
Publisher
Elsevier
Start Page
909
End Page
918
Journal / Book Title
European Journal of Vascular and Endovascular Surgery
Volume
61
Issue
6
Copyright Statement
© 2021 European Society for Vascular Surgery. Published by Elsevier B.V. All rights reserved. This manuscript is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International Licence http://creativecommons.org/licenses/by-nc-nd/4.0/
Subjects
Abdominal aortic aneurysm
Core outcome set
Cardiovascular System & Hematology
1102 Cardiorespiratory Medicine and Haematology
1103 Clinical Sciences
Publication Status
Published
Date Publish Online
2021-03-23