Cardiac resynchronization therapy in chronic heart failure with moderately reduced left ventricular ejection fraction: Lessons from the Multicenter InSync Randomized Clinical Evaluation MIRACLE EF study
File(s)1-s2.0-S0167527315304642-main.pdf (879.34 KB)
Published version
Author(s)
Type
Journal Article
Abstract
Background
The benefits of CRT for symptomatic heart failure (HF) patients with a wide QRS and reduced left ventricular ejection fraction (LVEF ≤ 35%), are well established .Post-hoc subgroup analyses suggest that CRT benefit may extend to patients with LVEF > 35%.
Methods
The MIRACLE EF was a prospective, randomized, controlled, double-blinded study to evaluate CRT-P in NYHA II–III HF patients with LBBB and with LVEF of 36%–50% and no previous pacing or ICD. The primary endpoint was a composite of time to first HF event or death. All patients were implanted with a CRT-P and randomized 2:1 to CRT-P ON or CRT-P OFF groups. The minimum follow up time was 24 months.
Results
The MIRACLE EF study was stopped for enrollment futility after 13 months and enrolling only 44 patients. The main difficulties in recruiting patients were lack of eligible patients, previous ICD implants, and the reluctance of institutions, patients or physicians to enroll in the study which included a potential 5 year CRT OFF period.
Conclusion
Despite a careful design, identification and randomization of eligible patients were challenging and a trial to assess morbidity and mortality trial was not feasible. The MIRACLE EF experience illustrates the difficulties of designing a scientifically robust but feasible study to assess potential new indications for implantable devices. Smaller randomized studies with surrogate endpoints may therefore be more reasonable, although the potential impact of such studies on clinical practice, guidelines, and reimbursement remain to be determined.
The benefits of CRT for symptomatic heart failure (HF) patients with a wide QRS and reduced left ventricular ejection fraction (LVEF ≤ 35%), are well established .Post-hoc subgroup analyses suggest that CRT benefit may extend to patients with LVEF > 35%.
Methods
The MIRACLE EF was a prospective, randomized, controlled, double-blinded study to evaluate CRT-P in NYHA II–III HF patients with LBBB and with LVEF of 36%–50% and no previous pacing or ICD. The primary endpoint was a composite of time to first HF event or death. All patients were implanted with a CRT-P and randomized 2:1 to CRT-P ON or CRT-P OFF groups. The minimum follow up time was 24 months.
Results
The MIRACLE EF study was stopped for enrollment futility after 13 months and enrolling only 44 patients. The main difficulties in recruiting patients were lack of eligible patients, previous ICD implants, and the reluctance of institutions, patients or physicians to enroll in the study which included a potential 5 year CRT OFF period.
Conclusion
Despite a careful design, identification and randomization of eligible patients were challenging and a trial to assess morbidity and mortality trial was not feasible. The MIRACLE EF experience illustrates the difficulties of designing a scientifically robust but feasible study to assess potential new indications for implantable devices. Smaller randomized studies with surrogate endpoints may therefore be more reasonable, although the potential impact of such studies on clinical practice, guidelines, and reimbursement remain to be determined.
Date Issued
2015-09-21
Date Acceptance
2015-09-19
Citation
International Journal of Cardiology, 2015, 202, pp.349-355
ISSN
1874-1754
Publisher
Elsevier
Start Page
349
End Page
355
Journal / Book Title
International Journal of Cardiology
Volume
202
Copyright Statement
© 2015 The Authors. Published by Elsevier Ireland Ltd. This is an open access article under the CC BY-NC-ND
license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
Subjects
Science & Technology
Life Sciences & Biomedicine
Cardiac & Cardiovascular Systems
Cardiovascular System & Cardiology
Heart failure
Cardiac resynchronization therapy
Left ventricular ejection fraction
LBBB
Mortality
BUNDLE-BRANCH BLOCK
SYSTOLIC DYSFUNCTION
TASK-FORCE
OUTCOMES
DEFIBRILLATOR
PREVALENCE
PREDICTORS
GUIDELINES
MORPHOLOGY
MORTALITY
Publication Status
Published