Role of crossmatch testing when Luminex-SAB is negative in renal transplantation
File(s)319315.pdf (1.01 MB)
Published version
Author(s)
Jayant, Kumar
Reccia, Isabella
Julie, Bridson M
Sharma, Ajay
Halawa, Ahmed
Type
Journal Article
Abstract
The human leukocyte antigen (HLA) system plays an important role in the acceptance of renal graft. Long and better graft survival has been reported in patients with HLA-identical siblings and a nonreactive cytotoxicity assay (CDC). New methods of HLA-typing and anti-HLA antibody detection techniques such as flow cytometry, solid-phase immunoassays, or antigen bead assays have further improved the outcomes of renal transplant recipients. In the present review, the explicit details of these methodologies are discussed in detail.
Date Issued
2018-02-28
Date Acceptance
2016-07-20
Citation
Polish Journal of Surgery, 2018, 90 (1), pp.41-46
ISSN
0032-373X
Publisher
Versita
Start Page
41
End Page
46
Journal / Book Title
Polish Journal of Surgery
Volume
90
Issue
1
Copyright Statement
© 2018 Fundacja Polski Przegląd Chirurgiczny. Published by Index Copernicus Sp. z o. o. All rights reserved. This material is available under the Creative Commons - Attribution 4.0 GB. The full terms of this license are available on: http://creativecommons.org/licenses/by-nc-sa/4.0/legalcode
Identifier
https://www.ncbi.nlm.nih.gov/pubmed/29513250
PII: 01.3001.0011.5959
Subjects
HLA-typing
anti-HLA antibody
human leukocyte antigen
renal transplant
Publication Status
Published
Coverage Spatial
Poland