Total average diastolic longitudinal displacement by colour tissue doppler imaging as an assessment of diastolic function
File(s)s12947-016-0083-2.pdf (1.79 MB)
Published version
Author(s)
Type
Journal Article
Abstract
Background
The current method for a non-invasive assessment of diastolic dysfunction is complex with the use of algorithms of many different echocardiographic parameters. Total average diastolic longitudinal displacement (LD), determined by colour tissue Doppler imaging (TDI) via the measurement of LD during early diastole and atrial contraction, can potentially be used as a simple and reliable alternative.
Methods
In 206 patients, using GE Healthcare Vivid E7 and 9 and Echopac BT11 software, we determined both diastolic LD, measured in the septal and lateral walls in the apical 4-chamber view by TDI, and the degree of diastolic dysfunction, based on current guidelines. Of these 206 patients, 157 had cardiac anomalies that could potentially affect diastolic LD such as severe systolic heart failure (n = 45), LV hypertrophy (n = 49), left ventricular (LV) dilation (n = 30), and mitral regurgitation (n = 33). Intra and interobserver variability of diastolic LD measures was tested in 125 patients.
Results
A linear relationship between total average diastolic LD and the degree of diastolic dysfunction was found. A total average diastolic LD of 10 mm was found to be a consistent threshold for the general discrimination of patients with or without diastolic dysfunction. Using linear regression, total average diastolic LD was estimated to fall by 2.4 mm for every increase in graded severity of diastolic dysfunction (β = −0.61, p-value <0.001). Patients with LV hypertrophy had preserved total average diastolic LD despite being classified as having diastolic dysfunction. Reproducibility of LD measures was acceptable.
Conclusions
There is strong evidence suggesting that patients with a total average diastolic LD under 10 mm have diastolic dysfunction.
The current method for a non-invasive assessment of diastolic dysfunction is complex with the use of algorithms of many different echocardiographic parameters. Total average diastolic longitudinal displacement (LD), determined by colour tissue Doppler imaging (TDI) via the measurement of LD during early diastole and atrial contraction, can potentially be used as a simple and reliable alternative.
Methods
In 206 patients, using GE Healthcare Vivid E7 and 9 and Echopac BT11 software, we determined both diastolic LD, measured in the septal and lateral walls in the apical 4-chamber view by TDI, and the degree of diastolic dysfunction, based on current guidelines. Of these 206 patients, 157 had cardiac anomalies that could potentially affect diastolic LD such as severe systolic heart failure (n = 45), LV hypertrophy (n = 49), left ventricular (LV) dilation (n = 30), and mitral regurgitation (n = 33). Intra and interobserver variability of diastolic LD measures was tested in 125 patients.
Results
A linear relationship between total average diastolic LD and the degree of diastolic dysfunction was found. A total average diastolic LD of 10 mm was found to be a consistent threshold for the general discrimination of patients with or without diastolic dysfunction. Using linear regression, total average diastolic LD was estimated to fall by 2.4 mm for every increase in graded severity of diastolic dysfunction (β = −0.61, p-value <0.001). Patients with LV hypertrophy had preserved total average diastolic LD despite being classified as having diastolic dysfunction. Reproducibility of LD measures was acceptable.
Conclusions
There is strong evidence suggesting that patients with a total average diastolic LD under 10 mm have diastolic dysfunction.
Date Issued
2016-09-17
Date Acceptance
2016-09-09
Citation
CARDIOVASCULAR ULTRASOUND, 2016, 14
ISSN
1476-7120
Publisher
BIOMED CENTRAL LTD
Journal / Book Title
CARDIOVASCULAR ULTRASOUND
Volume
14
Copyright Statement
© 2016 The Author(s). Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0
International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and
reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to
the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver
(http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and
reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to
the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver
(http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
Identifier
http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=WOS:000384359100002&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=1ba7043ffcc86c417c072aa74d649202
Subjects
Science & Technology
Life Sciences & Biomedicine
Cardiac & Cardiovascular Systems
Cardiovascular System & Cardiology
Echocardiography
Colour tissue Doppler imaging
Diastolic function
Diastolic longitudinal displacement
HEART-FAILURE
EUROPEAN ASSOCIATION
EJECTION FRACTION
AMERICAN SOCIETY
ECHOCARDIOGRAPHY
RECOMMENDATIONS
CONCORDANCE
DYSFUNCTION
PRESSURES
VELOCITY
Publication Status
Published
Article Number
ARTN 41
Date Publish Online
2016-09-17