Use of an automaton model to suggest methods for cessation of intractable fibrillatory activity
File(s) Automaton III revision clean.docx (25.02 MB)
Accepted version
Author(s)
Ciaccio, Edward J
Peters, Nicholas S
Garan, Hasan
Type
Journal Article
Abstract
BACKGROUND: Atrial fibrillation (AF) is the most common heart arrhythmia, and permanent AF is an intractable medical problem. If cessation of permanent AF were possible, via extensive substrate ablation or multisite stimulation, it could significantly improve the public health. METHOD: A cellular automaton composed of 576 × 576 computerized grid nodes, described in detail previously, was used to test hypotheses concerning the cessation of fibrillatory electrical activity. A refractory period gradient across the grid, and addition of randomly located nonconducting fibers, were utilized as conditions leading to fibrillatory activity. A premature S1-S2 stimulus was applied to one grid corner, resulting in unidirectional conduction block at some locations, followed by rotational activity and random propagation of activation wavelets throughout the grid, none of which terminated spontaneously. Simulated ablation lesions of dimension 20 × 20 grid nodes, imparted at core locations of rotational activity, and multisite electrode stimulation (MES) applied at nodes where recovery of excitability had occurred, were used in attempts to terminate fibrillatory activity. Six impositions of random fiber location were utilized in separate trials. RESULTS: Simulated ablation lesions eliminated the targeted swirling vortices; however, additional vortices then often appeared at other locations. After ablating approximately one third of the grid area, localized vortices were eliminated, but individual wavelets continued to propagate about longer viable pathways forming at ablation lesions. Thus extensive ablation was unsuccessful in terminating arrhythmia. However, MES applied uniformly throughout the grid, with a coupling interval slightly longer than the maximum refractory period, terminated fibrillatory activity in some trials. More efficaciously, application of MES with a coupling interval half the maximum refractory period of the grid succeeded in capture of activation at all nodes, and when followed by a doubling of the MES coupling interval, resulted in cessation of all fibrillatory activity. CONCLUSIONS: It is possible to terminate simulated fibrillatory activity in a computerized grid that would otherwise be intractable, using multisite stimulation with a coupling interval related to the maximum refractory period of the substrate. If each MES stimulating electrode could be individually controlled, it would be possible to apply a stimulation pattern mimicking the normal heart activation sequence.
Date Issued
2018-11-01
Date Acceptance
2018-07-31
Citation
Computers in Biology and Medicine, 2018, 102, pp.357-368
ISSN
0010-4825
Publisher
Elsevier
Start Page
357
End Page
368
Journal / Book Title
Computers in Biology and Medicine
Volume
102
Copyright Statement
© 2018 Elsevier Ltd. All rights reserved. This manuscript is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International Licence http://creativecommons.org/licenses/by-nc-nd/4.0/
Sponsor
British Heart Foundation
British Heart Foundation
British Heart Foundation
British Heart Foundation
British Heart Foundation
Rosetrees Trust
Rosetrees Trust
Imperial College Healthcare NHS Trust- BRC Funding
Identifier
https://www.ncbi.nlm.nih.gov/pubmed/30097173
PII: S0010-4825(18)30211-7
Grant Number
PG/10/37/28347
FS/14/46/30907
PG/16/17/32069
PG/16/17/32069
RG/16/3/32175
A1173/ M577
A1407/ M645
RDB02
Subjects
Ablation
Activation
Automaton
Capture
Fibrillation
Multisite pacing
Publication Status
Published
Coverage Spatial
United States
Date Publish Online
2018-08-02
