Abstract
fib Model Code 2010 (MC2010). MC2010 is based on the critical shear crack theory proposed by Muttoni, which relates shear resistance to the width of the so-called ‘critical shear crack’ which depends on slab rotation. Parametric studies are presented that show BS 8110 to require significantly less shear reinforcement within 1·5d (where d is the slab effective depth) of the loaded area than EC2 and MC2010, both of which have been extensively calibrated against test data. This raises the question of whether flat slabs designed to BS 8110 have an adequate factor of safety against punching failure. This question is explored using nonlinear finite-element modelling in conjunction with MC2010 Level IV. It is shown that punching resistance at internal columns can be increased significantly by restraint from the surrounding slab but the strength increase is variable and, in the case of uniformly loaded slabs, already largely included in BS 8110 and EC2.
Date Issued
2015-06-13
Date Acceptance
2015-04-10
Citation
Magazine of Concrete Research, 2015, 67 (24), pp.1315-1328
ISSN
1751-763X
Publisher
Thomas Telford (ICE Publishing)
Start Page
1315
End Page
1328
Journal / Book Title
Magazine of Concrete Research
Volume
67
Issue
24
Copyright Statement
© 2015 Thomas Telford Ltd. Original article available at http://www.icevirtuallibrary.com/content/article/10.1680/macr.14.00432;jsessionid=efjubbevdau7.x-telford-live-01. Permission is granted by ICE Publishing to print one copy for personal use. Any other use of these PDF files is subject to reprint fees.
Subjects
Building & Construction
0905 Civil Engineering
Publication Status
Published