Reconstructing full femoral geometry from corrupted CT scans: an automatic pipeline for revision knee arthroplasty planning
File(s) Supplementary Document.docx (101.99 KB) MANUSCRIPT_v1.docx (2.75 MB)
Supporting information
Accepted version
Author(s)
Type
Journal Article
Abstract
Aims
Revision total knee arthroplasty (TKA) demands accurate reconstruction of the native joint line and femoral alignment to restore knee biomechanics. However, preoperative assessment is often limited by metallic implants, cement spacers, or bone loss, which obscure key anatomical landmarks on computed tomography (CT) imaging. This study evaluated a deep learning–based reconstruction approach designed to restore the original native three-dimensional (3D) femoral geometry, prior to any joint replacement surgery. The inputs were CT scans of the type encountered during revision TKA planning, in which bone data are missing due to metal artefact and bone loss.
Methods
A femoral shape reconstruction model was trained on 377 full-leg CT scans from healthy individuals with no prior history of knee surgery and validated on an independent dataset of 15 cadaveric femora with knee osteoarthritis. Two clinically relevant revision scenarios were simulated: progressive distal bone loss (removal of 1–10% of femoral length), and implant-related bone defects mimicking distal femoral bone loss following implant removal. Reconstructions were compared with manual ground-truth models using Dice similarity coefficient (DSC), surface error as root-mean-square Euclidean distance (RMSE), and clinically relevant femoral alignment and morphology measurements (Wilcoxon signed-rank test, p < 0.05).
Results
Reconstructed femoral models were anatomically accurate. Baseline DSC across the 15 independent cadaveric femora averaged 97.5%, remaining 93.8% after simulated removal of 10% of distal femoral length. Condylar RMSE remained within 2 mm in 11/15 cases up to 7% of distal femoral bone removal. Under simulated implant removal, models achieved a DSC of 95.4%, with no statistically significant difference from manual ground-truth models on any other metric.
Conclusion
An automated deep learning tool can recreate native 3D femoral geometry and key angular/distance measurements from the incomplete CT imaging typical of revision TKA. This could improve outcomes by enabling preoperative 3D planning of the original joint line and limb alignment.
Revision total knee arthroplasty (TKA) demands accurate reconstruction of the native joint line and femoral alignment to restore knee biomechanics. However, preoperative assessment is often limited by metallic implants, cement spacers, or bone loss, which obscure key anatomical landmarks on computed tomography (CT) imaging. This study evaluated a deep learning–based reconstruction approach designed to restore the original native three-dimensional (3D) femoral geometry, prior to any joint replacement surgery. The inputs were CT scans of the type encountered during revision TKA planning, in which bone data are missing due to metal artefact and bone loss.
Methods
A femoral shape reconstruction model was trained on 377 full-leg CT scans from healthy individuals with no prior history of knee surgery and validated on an independent dataset of 15 cadaveric femora with knee osteoarthritis. Two clinically relevant revision scenarios were simulated: progressive distal bone loss (removal of 1–10% of femoral length), and implant-related bone defects mimicking distal femoral bone loss following implant removal. Reconstructions were compared with manual ground-truth models using Dice similarity coefficient (DSC), surface error as root-mean-square Euclidean distance (RMSE), and clinically relevant femoral alignment and morphology measurements (Wilcoxon signed-rank test, p < 0.05).
Results
Reconstructed femoral models were anatomically accurate. Baseline DSC across the 15 independent cadaveric femora averaged 97.5%, remaining 93.8% after simulated removal of 10% of distal femoral length. Condylar RMSE remained within 2 mm in 11/15 cases up to 7% of distal femoral bone removal. Under simulated implant removal, models achieved a DSC of 95.4%, with no statistically significant difference from manual ground-truth models on any other metric.
Conclusion
An automated deep learning tool can recreate native 3D femoral geometry and key angular/distance measurements from the incomplete CT imaging typical of revision TKA. This could improve outcomes by enabling preoperative 3D planning of the original joint line and limb alignment.
Date Acceptance
2026-10-05
Citation
Bone & Joint Research
ISSN
2046-3758
Publisher
The British Editorial Society of Bone & Joint Surgery
Journal / Book Title
Bone & Joint Research
Copyright Statement
Subject to copyright. This paper is embargoed until publication. Once published the Version of Record (VoR) will be available on immediate open access.
Publication Status
Accepted