Dual-balloon assisted super-selective embolisation of high flow arterial venous fistula within a transplant kidney
File(s)s42155-018-0029-x.pdf (1.08 MB)
Published version
Author(s)
ffrench-Constant, Sara
Weerakoon, Nisal
Amin, Rahul
Taube, David
Hamady, MS
Type
Journal Article
Abstract
Background
In this case report, we describe a novel application of the technique of ‘dual-balloon assisted’ cannulation and embolisation of a high flow arterial venous fistula (AVF) in transplant kidney, where attempts at standard and previously described embolisation techniques were proving difficult to achieve.
Case presentation
Seventy year old gentleman with renal transplant presenting with high output cardiac failure and deteriorating renal function. Angiography demonstrated high flow traumatic AV fistula within transplanted kidney, secondary to multiple biopsies. Attempts at guidewire and guiding sheath placement and stability for occlusion plug deployment were failing due to combination of very high back-flow pressures within the AVF and challenging vascular anatomy; with an aneurysmal, tortuous iliac artery as well as intra renal transplanted vessels. A combination of angioplasty and remodeling aortic balloons in the transplant artery and the host external iliac vein respectively, facilitated stabilization of guiding sheath and hence controlled delivery of an occlusion plug from the venous side of the fistula. The fistula was successfully embolised, leading to complete resolution of patient symptoms and improvement of renal function beyond his previous baseline.
Conclusions
Percutaneous embolisation is an established technique to treat iatrogenic AVF in transplant kidneys. High flow pressure through an AVF, as demonstrated in this case, can cause difficulty and raise safety issues in accessing and embolising the AVF using previously described techniques. This case report describes an effective and novel application of the technique of using a second balloon in the host common iliac vein to; lower flow pressure, stabilise the guidewires during plug deployment and prevent displacement of wires and/or plug into the common iliac vein.
In this case report, we describe a novel application of the technique of ‘dual-balloon assisted’ cannulation and embolisation of a high flow arterial venous fistula (AVF) in transplant kidney, where attempts at standard and previously described embolisation techniques were proving difficult to achieve.
Case presentation
Seventy year old gentleman with renal transplant presenting with high output cardiac failure and deteriorating renal function. Angiography demonstrated high flow traumatic AV fistula within transplanted kidney, secondary to multiple biopsies. Attempts at guidewire and guiding sheath placement and stability for occlusion plug deployment were failing due to combination of very high back-flow pressures within the AVF and challenging vascular anatomy; with an aneurysmal, tortuous iliac artery as well as intra renal transplanted vessels. A combination of angioplasty and remodeling aortic balloons in the transplant artery and the host external iliac vein respectively, facilitated stabilization of guiding sheath and hence controlled delivery of an occlusion plug from the venous side of the fistula. The fistula was successfully embolised, leading to complete resolution of patient symptoms and improvement of renal function beyond his previous baseline.
Conclusions
Percutaneous embolisation is an established technique to treat iatrogenic AVF in transplant kidneys. High flow pressure through an AVF, as demonstrated in this case, can cause difficulty and raise safety issues in accessing and embolising the AVF using previously described techniques. This case report describes an effective and novel application of the technique of using a second balloon in the host common iliac vein to; lower flow pressure, stabilise the guidewires during plug deployment and prevent displacement of wires and/or plug into the common iliac vein.
Date Issued
2018-10-30
Date Acceptance
2018-09-14
Citation
CVIR Endovascular, 2018, 1
ISSN
2520-8934
Publisher
Springer Nature
Journal / Book Title
CVIR Endovascular
Volume
1
Copyright Statement
© The Author(s). 2018 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0
International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and
reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to
the Creative Commons license, and indicate if changes were made.
International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and
reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to
the Creative Commons license, and indicate if changes were made.
Publication Status
Published
Article Number
ARTN 21