Abstract
A diagnostic capable of recording spatially and temporally resolved x-ray self-emission data was developed to characterize experiments on the MAGPIE pulsed-power generator. The diagnostic used two separate imaging systems: a pinhole imaging system with two-dimensional spatial resolution and a slit imaging system with one-dimensional spatial resolution. The two-dimensional imaging system imaged light onto the image plate. The one-dimensional imaging system imaged light onto the same piece of image plate and a linear array of silicon photodiodes. This design allowed the cross-comparison of different images, allowing a picture of the spatial and temporal distribution of x-ray self-emission to be established. The design was tested in a series of pulsed-power-driven magnetic-reconnection experiments.
Date Issued
2021-12-01
Date Acceptance
2021-11-21
Citation
Review of Scientific Instruments, 2021, 92 (12), pp.123507-123507
ISSN
0034-6748
Publisher
AIP Publishing
Start Page
123507
End Page
123507
Journal / Book Title
Review of Scientific Instruments
Volume
92
Issue
12
Copyright Statement
© 2021 Author(s). All article content, except where otherwise noted, is licensed under a Creative Commons Attribution (CC BY) license
(http://creativecommons.org/licenses/by/4.0/). https://doi.org/10.1063/5.0073174
(http://creativecommons.org/licenses/by/4.0/). https://doi.org/10.1063/5.0073174
License URL
Sponsor
U.S Department of Energy
U.S Department of Energy
U.S Department of Energy
U.S Department of Energy
Defense Threat Reduction Agency
Identifier
https://aip.scitation.org/doi/10.1063/5.0073174
Grant Number
675350-9958
416729-G
83228-10968
417677
HDTRA1-20-1-0001
Subjects
physics.plasm-ph
physics.plasm-ph
Applied Physics
02 Physical Sciences
03 Chemical Sciences
09 Engineering
Publication Status
Published